EasyManuals Logo
Home>York>Air Conditioner>12 SEER H*RC018 THRU 060

York 12 SEER H*RC018 THRU 060 User Manual

York 12 SEER H*RC018 THRU 060
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
036-21137-004 Rev. C (0505)
Unitary Products Group 9
*Requires 2FD Blower Time Delay unless a standard furnace is equipped with one.
** Refer to Quick Selection Chart for specific furnace match-up.
H2RC048S06
1375
1775
17 G1FA048S17 1575 45.5 34.1 12.00* 12.00 11.00
21 G1FA048S21 1575 46.5 34.9 12.00* 12.00 11.00
21,24 G1FA060S21,24 1575 48.0 36.0 12.50* 12.50 11.10
21 G1HA048H21 1550 46.0 33.6 12.00* 11.10
21 G1HA048H21T 1525 46.0 33.6 12.00* 11.11
24 G1HA060H24 1575 47.0 33.8 12.00* 11.10
24 G1HA060H24T 1575 47.0 33.8 12.00* 11.10
- G1HD048 1575 46.0 34.5 12.00* 12.00 10.80
- G1HD060 1575 47.5 35.6 12.40* 12.40 11.05
21 G1NA048S21D 1575 46.0 34.5 12.00* 12.00 10.70
17 G1UA048S17 1575 45.5 34.1 12.00* 12.00 11.00
21 G1UA048S21 1575 46.5 34.9 12.00* 12.00 11.00
21,24 G1UA060S21,24 1575 48.0 36.0 12.50* 12.50 11.10
17 G2FD046(S,H)17 1575 45.5 34.1 12.00* 12.00 10.80
21,24 G2FD048(S,H)21,24 1575 46.5 34.9 12.20* 12.20 10.90
24 G2FD060(S,H)24 1575 48.0 36.0 12.50* 12.50 11.10
24 G2FD061
H24 1575 48.5 36.4 12.50* 12.50 11.20
H1RC048S(25,46)
1400
1800
17 G1FA048S17 1500 44.5 32.9 12.00 10.50
21 G1FA048S21 1600 45.5 33.7 12.00 11.00
21,24 G1FA060S21,24 1600 47.0 34.8 12.50 11.45
- G1HD048 1600 45.0 33.3 12.00 11.15
- G1HD060 1600 46.5 36.1 12.40 11.40
21 G1NA048S21D 1400 46.0 34.0 12.00 11.20
17 G1UA048S17 1500 44.5 32.9 12.00 10.50
21 G1UA048S21 1600 45.5 33.7 12.00 11.00
21,24 G1UA060S21,24 1600 47.0 34.8 12.50 11.45
17 G2FD046(S,H)17 1500 44.5 32.9 12.00 10.50
21,24 G2FD048(S,H)21,24 1600 45.5 33.7 12.20 11.20
24 G2FD060(S,H)24 1600 47.0 34.8 12.50 11.45
24 G2FD061
H24 1600 47.5 35.2 12.50 11.50
H4RC060S06
1600
2200
21 G1FA060S21(T) 1800 56.5 43.4 12.00 10.10
- G1HD060 1800 55.5 42.8 11.75 10.00
24 G1NA060S24T 1800 55.5 42.1 11.75 10.00
21 G1UA060S21(T) 1800 56.5 43.4 12.00 10.10
24 G2FD060(S,H)24(T) 1800 56.5 43.4 12.00 10.10
24 G2FD061H24 1800 56.5 43.8 12.00 10.15
24 G1HA60S24(T) 1710 56.0 42.5 12.00 10.15
H2RC060S(25,46)
1600
2200
21,24 G1FA060S21,24 1800 57.5 42.6 12.00 10.40
24 G1HA060H24T 1800 57.5 41.4 12.00* 10.40
- G1HD060 2000 57.5 42.6 12.00 10.25
24 G1NA060S24T 1850 57.5 38.9 12.00* 10.50
21,24 G1UA060S21,24 1800 57.5 42.6 12.00 10.40
24 G2FD060(S,H)24 1800 57.5 42.6 12.00 10.40
24 G2FD061H24 1850 58.0 43.2 12.00 10.45
1. TXV = Use 1TV700 Series Kit.
COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Continued)
UNIT MODEL
FURNACE**
COIL
MODEL
COOLING
CFM RANGE
(Min.-max.)
WRATED CFM
NET MBH
SEER
W/O TXV
SEER + TXV
1
EER
TOTAL SENS.