Johnson Controls Unitary Products 11
5151060-YTG-F-1116
ACCESSORIES
Refer to Price Manual for specific model numbers where not
shown.
TXV Kits - Air handlers are shipped with “Flex-coils” without a
factory installed metering device. For added flexibility, an R-22
or R-410A TXV or piston can be field installed to meet your
refrigerant choice. All TXV kits are chatleff style and require no
brazing to install. Some models are available with a factory
installed TXV.
Electric Heaters - 6HK models shown under electrical data
include sequential operation and temperature dual limit
switches for safe, efficient operation. Service disconnects are
provided where shown.
Combustible Floor Base Accessory - If an electric heat
accessory which is rated for greater than zero clearance to
combustible surfaces is installed in these air handlers in the
downflow operating positions on a combustible floor, one of the
following combustible floor base accessory models is required:
S1-1FB1917, S1-1FB1921, S1-1FB1924.
Breaker Moisture Seal Accessory - A clear circuit breaker
moisture barrier seals the breakers from humidity and dust. The
flexibility of the clear cover allows circuit breakers to be turned
ON or OFF without removing the cover. The cover firmly
attaches to the access panel around the circuit breakers with
the use of double backed adhesive tape. To ensure that
moisture or dust does not contaminate circuit breakers, an S1-
02435672000, Circuit Breaker, Cover Seal may be ordered.
Thermostat - Compatible thermostat controls are available
through accessory sourcing. For optimum performance, these
outdoor units are fully compatible with our York touch screen
thermostat with proprietary (patent-pending) hexagon interface.
For more information, see the thermostat section of the Product
Equipment Catalog.
ELECTRICAL DATA FOR MULTI-SOURCE POWER SUPPLY: 208/230-3-60
Air Handlers
Models
Heater
Models
1
Heater Amps
@240V
Min. Circuit Ampacity
MOP
2
208V 230V 208V 230V
Circuit Circuit
1st
2
2nd
1st
2
2nd
1st
2
2nd
1st
2
2nd
36B 6HK46502025 46.2 31.3 25.0 33.3 27.6 35 25 35 30
36C 6HK46502025 46.2 31.3 25.0 33.3 27.6 35 25 35 30
42C 6HK46502025 46.2 31.3 25.0 33.3 27.6 35 25 35 30
48C 6HK46502025 46.2 34.1 25.0 36.4 27.6 35 25 40 30
48D
6HK46502025 46.2 34.1 25.0 36.4 27.6 35 25 40 30
6HK46502525 57.7 40.4 31.3 43.3 34.6 45 35 45 35
60C 6HK46502025 46.2 34.1 25.0 36.4 27.6 35 25 40 30
60D
6HK46502025 46.2 34.1 25.0 36.4 27.6 35 25 40 30
6HK46502525 57.7 40.4 31.3 43.3 34.6 45 35 45 35
1. The 20kW and 25kW heater models (6HK46502025 and 6HK46502525) come with service disconnects standard.
2. MOP = Maximum Overcurrent Protection device; must be HACR type circuit breaker or time delay fuse. The 1st circuit includes blower motor amps.
Refer to the latest edition of the National Electric Code or in Canada the Canadian electrical Code and local codes to determine correct wire sizing.
POWER WIRING - LINE CONNECTIONS
),(/'32:(5:,5,1*
9
&20321(17&2'(6
*1'*5281'/8*
6'6(59,&(',6&211(&7
&.7&,5&8,7
&1:,5(&211(&725187
*1'
12(/(&75,&+($7
32:(5
6833/<
&1
&1
*1'
-803(5%$5
6,1*/(6285&(32:(5
08/7,6285&(32:(5
08/7,6285&(32:(5
:,7+-803(5%$5
7(50,1$/%/2&.25
6(59,&(',6&211(&7
32:(5
6833/<
32:(5
6833/<
6,1*/(6285&(32:(5
&,5&8,7621N:N:
&,5&8,7621N:
7(50,1$/%/2&.25
6(59,&(',6&211(&7
&.7
&.7
32:(5
6833/<
6'
6'
6'
6'
6'
32:(5
6833/<
*1'
*1'
*1'
*1'
32:(5
6833/<
/
/
/
/
/
/
&.7
/
/
/
/
6'
6'
6'
/
/
/
/
/
/
/
/
/
08/7,6285&(32:(5
&.7
&.7
&,5&8,7621N:N:
&,5&8,7621N:
3+$6((/(&75,&+($7237,216
3+$6((/(&75,&+($732:(5237,216
$
SINGLE SOURCE POWER ACCESSORIES (SINGLE PHASE)
S1-02435670000 For heat kits with 2 service disconnects.
S1-02435671000 For heat kits with 3 service disconnects.
SINGLE SOURCE POWER ACCESSORY (THREE PHASE)
S1-32436041000
Contains a terminal block and wiring to
connect service disconnects together.