NORMAL MAINTENANCE
CAUTION: Prior to any of the following maintenance proce-
dures, shut off all power to the unit to prevent
personal injury.
FILTERS - Inspect once a month. Replace disposable or clean
permanent type as necessary. DO NOT replace permanent
type with disposable.
MOTORS - Indoor fan and outdoor fan motors are permanently
lubricated and require no maintenance.
MAINTENANCE
OUTDOOR COIL - Dirt should not be allowed to accumulate
on the outdoor coil surface or other parts in the air circuit.
Cleaning should be as often as necessary to keep coil clean.
Use a brush, vacuum cleaner attachment, or other suitable
means. If water is used to clean coil, be sure power to the unit
is shut off prior to cleaning.
NOTE: Exercise care when cleaning the coil so that the coil
fins are not damaged.
Do not permit the outdoor air discharge to be obstructed by
overhanging structures of shrubs.
Unitary Products Group
P.O. Box 1592, York, Pennsylvania USA 17405-1592
Subject to change without notice. Printed in U.S.A.
Copyright
by York International Corporation 1997. All Rights Reserved.
530.18-N7Y
208/230, 575 VOLT
MODELS ONLY
208/230-1-60 VOLT
MODELS ONLY
208/230, 460 VOLT
MODELS ONLY

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York D4CE 036 and is the answer not in the manual?

York D4CE 036 Specifications

General IconGeneral
BrandYork
ModelD4CE 036
CategoryAir Conditioner
LanguageEnglish

Related product manuals