Unitary Products Group 3
Nominal external static pressure is 0.50” w.c. at furnace outlet ahead of cooling coils.
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
RATINGS & PHYSICAL / ELECTRICAL DATA - UPFLOW MODELS
Models
Input Output Nominal Airflow Cabinet Width
Total
Unit
AFUE
Air Temp.
Rise
MBH MBH CFM In. Amps °F
G8C05012(MU,MD)B12 50 40 1200 17-1/2 8.0 80.0 30-60
G8C07512(MU,MD)B12 75 60 1200 17-1/2 8.0 80.0 35-65
G8C07516(MU,MD)C12 75 60 1600 21 11.4 80.0 30-60
G8C10016(MU,MD)C12 100 80 1600 21 11.4 80.0 40-70
G8C10020(MU,MD)D11 100 80 2000 24 1/2 11.3 80.0 35-65
G8C12520(MU,MD)D11 125 100 2000 24 1/2 11.3 80.0 40-70
G8C15020UHD11 150 120 2000 24 1/2 11.3 80.0 40-70
Models
Input
Max. Outlet
Air Temp
Blower
Blower
Size
Max
Over-current
protect
Min.Wire Size
(awg) @ 75 ft.
one way
Operation
Wt.
MBH °F Hp Amps In. LBS
G8C05012(MU,MD)B12 50 160 1/2 7.0 10 x 8 15 14 112
G8C07512(MU,MD)B12 75 165 1/2 7.0 10 x 8 15 14 118
G8C07516(MU,MD)C12 75 160 1/2 10.4 10 x 10 15 14 129
G8C10016(MU,MD)C12 100 170 1/2 10.4 10 x 10 15 14 135
G8C10020(MU,MD)D11 100 165 1 10.3 (2)10 x 6 15 14 149
G8C12520(MU,MD)D11 125 170 1 10.3 (2)10 x 6 15 14 155
G8C15020UHD11 150 170 1 10.3 (2)10 x 6 15 14 165