EasyManuals Logo
Home>York>Heat Pump>MC SEries

York MC SEries User Manual

York MC SEries
10 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
841890-UIM-B-0612
3
TABLE 2: Dimensions
- FC Coils
Models
Dimensions
1
Refrigerant
Connections
2
Height Width Opening Widths Line Size
ABCDLiquidVapor
FC18A 18 14 1/2 13 3/8 13 1/2
3/8
3/4
FC18B 18 17 1/2 16 3/8 16 1/2
FC24A 22 14 1/2 13 3/8 13 1/2
FC24B 22 17 1/2 16 3/8 16 1/2
FC30A 22 14 1/2 13 3/8 13 1/2
FC30B 22 17 1/2 16 3/8 16 1/2
FC32A 20 14 1/2 13 3/8 13 1/2
FC35B 20 17 1/2 16 3/8 16 1/2
FC35C 24 1/2 21 19 7/8 20
FC36A 24 1/2 14 1/2 13 3/8 13 1/2
7/8FC36B 24 1/2 17 1/2 16 3/8 16 1/2
FC36C 24 1/2 21 19 7/8 20
FC37A 24 1/2 14 1/2 13 3/8 13 1/2 3/4
FC42B 28 17 1/2 16 3/8 16 1/2
7/8
FC42C 28 21 19 7/8 20
FC43B 24 1/2 17 1/2 16 3/8 16 1/2
FC43C 24 1/2 21 19 7/8 20
FC48C 28 21 19 7/8 20
FC48D 28 24 1/2 23 3/8 23 1/2
FC60C 28 21 19 7/8 20
FC60D 28 24 1/2 23 3/8 23 1/2
FC62D 32 24 1/2 23 3/8 23 1/2
FC64D 36 24 1/2 23 3/8 23 1/2
1. All dimensions are in inches.
2. Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.
20 3/8”
(Opening)
B
C
3/4” Flange
A
21 1/2”
BOTTOM
OPENING
DIMENSIONS
D
20 1/4”
TABLE 3: Dimensions - PC Coils
Models
Dimensions
1
Refrigerant
Connections
2
Height Width Opening Widths Line Size
ABCDLiquidVapor
PC18A 17 3/4 14 1/2 13 3/8 13 1/2
3/8
3/4
PC18B 17 17 1/2 16 3/8 16 1/2
PC24A 21 7/8 14 1/2 13 3/8 13 1/2
PC24B 21 3/8 17 1/2 16 3/8 16 1/2
PC30A 21 7/8 14 1/2 13 3/8 13 1/2
PC30B 21 3/8 17 1/2 16 3/8 16 1/2
PC32A 20 14 1/2 13 3/8 13 1/2
PC35B 18 7/8 17 1/2 16 3/8 16 1/2
PC35C 18 3/4 21 19 7/8 20
PC36A 23 7/8 14 1/2 13 3/8 13 1/2
7/8PC36B 23 1/8 17 1/2 16 3/8 16 1/2
PC36C 22 7/8 21 19 7/8 20
PC37A 23 7/8 14 1/2 13 3/8 13 1/2 3/4
PC42B 27 5/8 17 1/2 16 3/8 16 1/2
7/8
PC42C 27 1/8 21 19 7/8 20
PC43B 23 1/8 17 1/2 16 3/8 16 1/2
PC43C 22 5/8 21 19 7/8 20
PC48C 25 3/8 21 19 7/8 20
PC48D 24 5/8 24 1/2 23 3/8 23 1/2
PC60C 27 1/2 21 19 7/8 20
PC60D 26 7/8 24 1/2 23 3/8 23 1/2
1. All dimensions are in inches.
2. Refrigerant line sizes may require larger lines for extended line lengths. See York bulletin #690.01-AD1V for details.
20 3/8”
(Opening)
B
C
(Opening)
12”
A
21 1/2”
BOTTOM
OPENING
DIMENSIONS
20 1/4”
D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York MC SEries and is the answer not in the manual?

York MC SEries Specifications

General IconGeneral
BrandYork
ModelMC SEries
CategoryHeat Pump
LanguageEnglish

Related product manuals