6
HIGH WALL
PREPARATION BEFORE INSTALLATION
• Before doing any work, check the interior power supply cord and the main breaker capacity are sufficient and the
installation area is sufficient and complies with the requirements.
• Check that the power supply available agrees with nameplate voltage.
• Electrical work, wiring and cables must be performed in compliance with national and local wiring codes and
standard.
• Do not use the extension cables. In the case extended cables are needed, use the terminal block.
SELECTION OF THE LOCATION
• Select a place which provides the space around the units as shown in the diagram below.
Models
MHC-MHH/BOC-BOH
07 09 12 18 25
A 60cm 60cm 60cm 60cm 60cm
B 70cm 70cm 70cm 70cm 70cm
C 60cm 60cm 60cm 60cm 60cm
D 10cm 10cm 10cm 10cm 10cm
Models
MHC-MHH/BOC-BOH
07 09 12 18 25
A 20cm 20cm 20cm 20cm 20cm
B 60cm 60cm 60cm 60cm 60cm
C 40cm 40cm 40cm 40cm 40cm
D 20cm 20cm 20cm 20cm 20cm
Outdoor
Cautions
• Do not install in a place that cannot bear the weight of the unit.
Indoor
BO 07-12
BO 18
BO 25
497133.5 133.5
248
230
268
429
150 550 150
100100
64
64
234
315
287 2424
335
517
144
144
296
260
316
02_MHC/BOH 07-25.p65 18/3/02, 16:316