EasyManuals Logo
Home>York>Air Handlers>ND120-240

York ND120-240 User Manual

York ND120-240
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
505428-YTG-V-0417
Johnson Controls Unitary Products 49
PC180 / NC180 / NL180
Air Over Evaporator Coil
Capacity
1
&
kW
1
These capacities do not include the supply air blower motor heat. For net capacity, add motor heat, MBh. Example: Refer to the appropriate
Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 nameplate rated
motor efficiency.
Outdoor Temperature (°F @ 72% RH)
CFM DB (°F) -10 0 10 20 30 40 50 60
4500
55
MBH 68.2 80.0 93.8 110.0 129.1 151.5 177.8 208.7
KW 11.8 12.2 12.7 13.2 13.7 14.1 14.6 15.1
70
MBH 61.5 73.2 87.0 103.2 122.3 144.7 171.0 201.9
KW 13.5 14.0 14.4 14.9 15.4 15.9 16.3 16.8
80
MBH 57.6 69.3 83.1 99.3 118.4 140.8 167.1 198.0
KW 15.0 15.5 16.0 16.4 16.9 17.4 17.9 18.3
6000
55
MBH 74.0 85.8 99.6 115.8 134.9 157.3 183.6 214.5
KW 11.2 11.7 12.2 12.6 13.1 13.6 14.1 14.6
70
MBH 67.3 79.0 92.8 109.0 128.1 150.5 176.8 207.7
KW 12.9 13.4 13.9 14.4 14.8 15.3 15.8 16.3
80
MBH 63.4 75.1 88.9 105.1 124.2 146.6 172.9 203.8
KW 14.5 14.9 15.4 15.9 16.4 16.8 17.3 17.8
7500
55
MBH 72.4 84.1 97.9 114.1 133.2 155.6 181.9 212.8
KW 12.0 12.5 13.0 13.4 13.9 14.4 14.9 15.4
70
MBH 65.6 77.3 91.1 107.4 126.4 148.8 175.1 206.0
KW 13.7 14.2 14.7 15.2 15.6 16.1 16.6 17.1
80
MBH 61.7 73.4 87.3 103.5 122.5 144.9 171.2 202.1
KW 15.3 15.7 16.2 16.7 17.2 17.6 18.1 18.6
PD180 / ND180 / NM180
Air Over Evaporator Coil
Capacity
1
&
kW
1
These capacities do not include the supply air blower motor heat. For net capacity, add motor heat, MBh. Example: Refer to the appropriate
Blower Performance Table for the BHP of the supply air blower motor, MBh = 3.415 x kW and kW = BHP x 0.746 nameplate rated
motor efficiency.
Outdoor Temperature (°F @ 72% RH)
CFM DB (°F) -10 0 10 20 30 40 50 60
4500
55
MBH 65.6 77.0 90.3 105.8 123.9 145.1 169.7 198.5
KW 10.0 10.5 11.1 11.6 12.2 12.7 13.3 13.8
70
MBH 62.2 73.6 86.9 102.4 120.5 141.6 166.3 195.1
KW 12.0 12.5 13.1 13.6 14.2 14.7 15.3 15.8
80
MBH 59.5 70.9 84.1 99.7 117.8 138.9 163.6 192.4
KW 13.4 13.9 14.5 15.0 15.6 16.1 16.7 17.2
6000
55
MBH 71.6 83.0 96.3 111.8 129.9 151.0 175.7 204.5
KW 9.6 10.2 10.7 11.3 11.8 12.4 12.9 13.4
70
MBH 68.1 79.5 92.8 108.3 126.5 147.6 172.3 201.1
KW 11.6 12.2 12.7 13.3 13.8 14.3 14.9 15.4
80
MBH 65.4 76.8 90.1 105.6 123.7 144.9 169.6 198.3
KW 13.0 13.6 14.1 14.7 15.2 15.8 16.3 16.9
7500
55
MBH 74.0 85.4 98.7 114.2 132.4 153.5 178.2 207.0
KW 11.3 11.8 12.4 12.9 13.5 14.0 14.6 15.1
70
MBH 70.6 82.0 95.3 110.8 128.9 150.1 174.7 203.5
KW 13.3 13.8 14.4 14.9 15.5 16.0 16.6 17.1
80
MBH 67.9 79.3 92.6 108.1 126.2 147.4 172.0 200.8
KW 14.7 15.3 15.8 16.4 16.9 17.5 18.0 18.5