036-21476-002-E-0904
Unitary Products Group 3
PRODUCT NOMENCLATURE
15-25T Sunline 2000™ Model Number Nomenclature
D M 240 N 24 A 2 A AA 1
Product Category
D = Air Cond., Single Package
Product Generation
1 = First Generation
Product Identifier
M = R-22 Standard Efficiency
Installation Options
Additional Options
A = No Options Installed
(See Next Page)
Voltage B = Option 1
C = Option 2
2 = 208/230-3-60
4 = 460-3-60
5 = 575-3-60
D = Options 1 & 2
Nominal Cooling
Capacity - MBH
E = Option 3
180 = 15 Ton
F = Options 4
G = Options 1 & 3
240 = 20 Ton
300 = 25 Ton
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
A = Std Motor/Drive
L = Options 1,3 & 4
B = Std Mtr/Drive/Single Input Econo
M = Options 1, 2, 3, & 4
C = Std Mtr/Drive/Single Input Econo/Power Exhaust*
N = Options 2 & 3
D = Std Mtr/Drive/Motorized Damper
P = Options 2 & 4
Heat Type & Nominal Heat Capacity
F = Std Mtr/Drive/4" Filters
Q = Options 2, 3, & 4
C00 = Cooling Only. No field installed electric heat
G = Std Mtr/Drive/4" Filters/Single Input Econ
R = Options 3 & 4
Gas Heat Options
H = Std Mtr/Drive/4" Filters/Single Input Econ/Power Exhaust*
S = Option 5
N24 = 240 MBH Output Aluminized Steel
N32 = 320 MBH Output Aluminized Steel
S24 = 240 MBH Stainless Steel
S32 = 320 MBH Stainless Steel
L = Std Mtr/Drive/BAS Ready Econ (No BAS Controller) w/2" Pleated Filters
T = Options 1 & 5
M = Std Mtr/Drive/BAS Ready Econ (No BAS Controller)/Power Exhaust w/2" Pleated Filters*
U = Options 1, 3, & 5
N = Hi Static Drive
V = Options 1, 4, & 5
P = Hi Static Drive/Single Input Econo
W = Options 1, 3, 4, & 5
Electric Heat Options
Q = Hi Static Drive/Single Input Econo/Power Exhaust*
X = Options 3 & 5
E18 = 18 KW
R = Hi Static Drive/Motorized Damper
Y = Options 4 & 5
E36 = 36 KW
T = Hi Static Drive/4" Filters
Z = Options 3, 4, & 5
E54 = 54 KW
U = Hi Static Drive/4" Filters/Single Input Econ
Options
E72 = 72 KW
V = Hi Static Drive/4" Filters/Single Input Econ/Power Exhaust*
1 = Disconnect
Y = Hi Static Drive/BAS Ready Econ (No BAS Controller) w/2" Pleated Filters
2 = Non-Pwr'd Conv Oultet
Z = Hi Static Drive/BAS Ready Econ (No BAS Controller)/Power Exhaust w/2" Pleated Filters*
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Airflow
York Brand

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York Sunline 2000 DM 180 Series and is the answer not in the manual?

York Sunline 2000 DM 180 Series Specifications

General IconGeneral
BrandYork
ModelSunline 2000 DM 180 Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals