EasyManuals Logo
Home>York>Furnace>TL9E100

York TL9E100 User Manual

York TL9E100
34 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
5894307-UIM-B-0920
16 Johnson Controls Ducted Systems
Note: Dimensions are those required in Standard ASTM D-3311.
Example:
An 80,000 BTUH furnace requires 32 ft of pipe and five 90º elbows.
Using 2 in. pipe and standard elbows, the total equivalent length is:
This exceeds the 65 ft maximum equivalent length of 2 in. pipe allowed
for that model and is
not acceptable.
By using sweep elbows, the total equivalent length is:
This is less than the 65 ft maximum equivalent length of 2 in. pipe
allowed for that model and is acceptable.
Alternatively, using 3 in. pipe and standard elbows, the total equivalent
length is:
This is less than the 90 ft maximum equivalent length of 3 in. pipe
allowed for that model and is acceptable.
Table 5:
Maximum Equivalent Pipe Length
Elevation Sea level–2000
Model Input (BTUH) Pipe Size (in.) Max. Equivalent Length (ft)
60,000 2 65
60,000 3 90
60,000 4 150
80,000 2 65
80,000 3 90
80,000 4 150
100,000 2 30
100,000 3 90
100,000 4 150
Elevation 2001–4000
Model Input (BTUH) Pipe Size (in.) Max. Equivalent Length (ft)
60,000 2 55
60,000 3 80
60,000 4 145
80,000 2 55
80,000 3 80
80,000 4 145
100,000 2 20
100,000 3 80
100,000 4 145
Elevation 4001–5000
Model Input (BTUH) Pipe Size (in.) Max. Equivalent Length (ft)
60,000 2 50
60,000 3 75
60,000 4 140
80,000 2 50
80,000 3 75
80,000 4 140
100,000 2 15
100,000 3 75
100,000 4 140
Elevation 5001–7800
Model Input (BTUH) Pipe Size (in.) Max. Equivalent Length (ft)
60,000 2 45
60,000 3 70
60,000 4 135
80,000 2 35
80,000 3 70
80,000 4 135
100,000 2 10
100,000 3 70
100,000 4 135
Figure 18:
Elbow Dimensions
A
A
A
A
STANDARD ELBOW
LONG (SWEEP) ELBOW
Table 6: Elbow Dimensions
Elbow A Dimension (Illustrated in Figure 18)
2 in. Standard 2 5/16 in.
3 in. Standard 3 1/16 in.
2 in. Sweep 3 1/4 in.
3 in. Sweep 4 1/16 in.
Table 7:
Equivalent Length of Fittings
Fitting Equivalent Length
2 in. 90° sweep elbow 5 ft of 2 in. pipe
2 in. 45° sweep elbow 2 1/2 ft of 2 in. pipe
2 in. 90° standard elbow 7 ft of 2 in. pipe
2 in. 45° standard elbow 3 1/2 ft of 2 in. pipe
3 in. 90° sweep elbow 5 ft of 3 in. pipe
3 in. 45° sweep elbow 2 1/2 ft of 3 in. pipe
3 in. 90° standard elbow 7 ft of 3 in. pipe
3 in. 45° standard elbow 3 1/2 ft of 3 in. pipe
4 in. 90° elbow (sweep or standard) 5 ft of 4 in. pipe
4 in. 45° elbow (sweep or standard) 2 1/2 ft of 4 in. pipe
2 in. corrugated connector 10 ft of 2 in. pipe
3 in. corrugated connector 10 ft of 3 in. pipe
4 in. corrugated connector 10 ft of 4 in. pipe
32 ft of 2 in. pipe = 32 equivalent ft
5 - 90º standard 2 in. elbows = (5 x 7) = 35 equivalent ft
Total = 67 equivalent ft of 2 in. pipe
32 ft of 2 in. pipe = 32 equivalent ft
5 - 90º sweep 2 in. elbows = (5 x 5) = 25 equivalent ft
Total = 57 equivalent ft of 2 in. pipe
32 ft of 3 in. pipe = 32 equivalent ft
5 - 90º standard 3 in. elbows = (5 x 7) = 35 equivalent ft
Total = 67 equivalent ft of 3 in. pipe
Table 8: Combustion Air Intake and Vent Connection Size at Furnace
(All Models)
FURNACE VENT CONNECTION SIZES
Furnace Input All
Intake Pipe Size 2 in. (5.1 cm)
Vent Pipe Size 2 in. (5.1 cm)
IMPORTANT: Furnace vent pipe connections are sized for 2 in.
(5.1 cm) pipe. Any pipe size change must be made outside the fur-
nace casing in a vertical pipe section to allow proper drainage of con-
densate. An offset using two 45º (degree) elbows is required for
plenum clearance when the vent is increased to 3 in. (7.6 cm).