628792-BTG-G-0418
4 Ducted Systems
Condensing Unit Features and Benefits
Meets or exceeds ASHRAE 90.1 standards.
Scroll compressors provide both high efficiency and reli-
ability.
Simplicity
®
SE Controls
Dual refrigerant circuits.
Condenser coils are constructed of copper tubes and
aluminum fins for durability and long lasting efficient
operation.
Crankcase heaters that will be de-energized when the
compressor is operating.
Both high and low pressure controls. Since these con-
trols are self-contained, there are no capillary lines to be
damaged.
Solid state or internal line break compressor motor pro-
tection.
Class 2, 24-volt thermostat control circuit.
Factory installed service valves are standard.
Two filter-driers are shipped in the unit's control box for
field installation in the liquid line near the condensing
unit.
Copper stub-outs are factory mounted on the suction
and liquid line service valves to simplify the field piping
connections.
Multiple controls to provide stable system operation at
ambient temperatures down to 40ºF with kits available
for operation to 0ºF.
Capacity staging for more economical operation and
more even temperature levels within the conditioned
space.
A lockout circuit to prevent the unit from cycling on safety
control.
Pump-out on unit startup to prevent liquid refrigerant
returning to the compressor is standard on all models.
Inherently protected condenser fan motors.
V-Coil Design with exterior service port connections.
Five-minute anti-short cycle timer and minimum com-
pressor run time.
Factory installed disconnect and Technicoat coils option.
Self contained high and low pressure controls.
Condensing Unit Accessories
Low ambient VFD control to 0° F.
Phase Monitors - Designed to prevent unit damage. The
phase monitor will shut the unit down and out-of phase
condition.
Hot Gas Bypass Kit - That will provide a metered flow of
compressor discharge gas to the system’s evaporator
coil during reduced load operation.
Optional skid for fork truck handling (requires 96” length