NOTES:
1) The BRUSH / SR2 and HB inputs could be connected to Battery Negative (B8). It is
necessary to change the internal link “B” from 1-2 to 2-3. In this case the Normally
Closed microswitches need to be Normally Open, and the Normally Open
microswitches need to be Normally Closed.
2) The REV, FW, SR1, PB, SEAT inputs could be connected to Battery Negative (E9).
It is necessary to change the internal link “A” from 1-2 to 2-3. In this case the Nor-
mally Closed microswitches need to be Normally Open, and the Normally Open
Microswitches need to be normally Closed.
3) The MOTOR THERM, BACK FW, BACK REV, ENABLE/ SR3, FREE inputs could
be connected to Battery Negative (F1 or F2). It is necessary to change the internal
link “C” from 1-2 to 2-3. In this case the Normally Closed microswitches need to be
Normally Open, and the Normally Open Microswitches need to be Normally Closed.
3.5 DESCRIPTION OF POWER CONNECTIONS
+BATT = Positive Supply from Battery.
-BATT = Negative Supply from Battery.
VMN = Negative Supply (via chopper) to Motor.
F1, F2 = Connections to Drive Motor Field Winding.

Other manuals for Zapi ZAPIMOS Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zapi ZAPIMOS Series and is the answer not in the manual?

Zapi ZAPIMOS Series Specifications

General IconGeneral
BrandZapi
ModelZAPIMOS Series
CategoryInverter
LanguageEnglish

Related product manuals