EasyManuals Logo
Home>Zebra>Barcode Reader>RFD8500

Zebra RFD8500 Quick Start Guide

Zebra RFD8500
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Zebra reserves the right to make changes to any product to improve
reliability, function, or design. Zebra does not assume any product liability
arising out of, or in connection with, the application or use of any product,
circuit, or application described herein. No license is granted, either
expressly or by implication, estoppel, or otherwise under any patent right or
patent, covering or relating to any combination, system, apparatus,
machine, material, method, or process in which Zebra products might be
used. An implied license exists only for equipment, circuits, and subsystems
contained in Zebra products.
Warranty
For the complete Zebra hardware product warranty statement, go to:
http://www.zebra.com/warranty.
For Australia Only
This warranty is given by Zebra Technologies Asia Pacific Pte. Ltd., 71
Robinson Road, #05-02/03, Singapore 068895, Singapore. Our goods
come with guarantees that cannot be excluded under the Australia
Consumer Law. You are entitled to a replacement or refund for a major
failure and compensation for any other reasonably foreseeable loss or
damage. You are also entitled to have the goods repaired or replaced if the
goods fail to be of acceptable quality and the failure does not amount to a
major failure. Zebra Technologies Corporation Australia’s limited warranty
above is in addition to any rights and remedies you may have under the
Australian Consumer Law. If you have any queries, please call Zebra
Technologies Corporation at +65 6858 0722. You may also visit our website:
http://www.zebra.com for the most updated warranty terms.
RFD8500
REGULATORY GUIDE
Zebra Technologies Corporation
Lincolnshire, IL U.S.A.
http://www.zebra.com
Zebra and the Zebra head graphic are registered trademarks of ZIH
Corp. The Symbol logo is a registered trademark of Symbol
Technologies, Inc., a Zebra Technologies company.
© 2015 Symbol Technologies, Inc.
MN002062A01 Revision 2 — May 2015
Regulatory Information
This guide applies to the following Model Numbers: RFD8500. All
Zebra devices are designed to be compliant with rules and
regulations in locations they are sold and will be labeled as
required. Local language translations are available at the following
website:
http://www.zebra.com/support.
Any changes or modifications to Zebra equipment, not expressly
approved by Zebra, could void the user's authority to operate the
equipment.
Antennas: Use only the supplied or an approved replacement
antenna. Unauthorized antennas, modifications, or attachments
could cause damage and may violate regulations.
CAUTION:
Only use Symbol approved and UL Listed accessories, battery
packs and battery chargers.
Do NOT attempt to charge damp/wet mobile computers or
batteries. All components must be dry before connecting to an
external power source.
Declared maximum operating temperature: 40°C.
Bluetooth
®
Wireless Technology
This is an approved Bluetooth
®
product. For more information or
to view End Product Listing, please visit:
https://www.bluetooth.org/tpg/listings.cfm.
Wireless Devices Country Approvals
Regulatory markings, subject to certification, are applied to the
device signifying the radio(s) is/are approved for use in the
following countries: United States, Canada, Japan, China, S.
Korea, Australia, and Europe.
Please refer to the Declaration of Conformity (DoC) for details of
other country markings. This is available at:
http://www.zebra.com/doc
Note: Europe includes Austria, Belgium, Bulgaria, Croatia, Czech
Republic, Cyprus, Denmark, Estonia, Finland, France, Germany,
Greece, Hungary, Iceland, Ireland, Italy, Latvia, Liechtenstein,
Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland,
Portugal, Romania, Slovak Republic, Slovenia, Spain, Sweden,
Switzerland and the United Kingdom.
Health and Safety Recommendations
Ergonomic Recommendations
Reduce or eliminate repetitive motion
Maintain a neutral postures
Reduce or eliminate excessive force
Keep objects that are used frequently within easy reach
Perform tasks at correct heights
Reduce or eliminate vibration
Reduce or eliminate direct pressure
Provide adjustable workstations
Provide adequate clearance
Provide a suitable working environment
Improve work procedures.
Please observe all warning notices with regard to the usage of
wireless devices.
Wireless devices transmit radio frequency energy and may affect
medical electrical equipment.
Wireless devices should be switched off wherever you are
requested to do so in hospitals, clinics or healthcare facilities.
These requests are designed to prevent possible interference with
sensitive medical equipment.
Pacemakers
Pacemaker manufacturers recommended that a minimum of 15cm
(6 inches) be maintained between a hand-held wireless device
and a pacemaker to avoid potential interference with the
pacemaker. These recommendations are consistent with
independent research and recommendations by Wireless
Technology Research.
Persons with Pacemakers:
Should ALWAYS keep the device more than 15cm (6 inches)
from their pacemaker when turned ON.
Should not carry the device in a breast pocket.
Should use the ear furthest from the pacemaker to minimize the
potential for interference.
If you have any reason to suspect that interference is taking
place, turn OFF your device.
Other Medical Devices
Please consult your physician or the manufacturer of the medical
device, to determine if the operation of your wireless product may
interfere with the medical device.
Safety Information
Reducing RF Exposure - Use Properly
Only operate the device in accordance with the instructions
supplied.
International
The device complies with internationally recognized standards
covering human exposure to electromagnetic fields from radio
devices. For information on "International" human exposure to
electromagnet fields refer to the Zebra Declaration of Conformity
(DoC) at http://www.zebra.com/doc located under Wireless
Communications and Health.
For further information on the safety of RF energy from wireless
devices see
https://www.zebra.com/us/en/about-zebra/company-information/
corporate-responsibility.html.
Europe
Hand-held Devices
To comply with EU RF exposure requirements, this device must be
operated in the hand with a minimum separation distance of 23cm
or more from a person's body. Other operating configurations
should be avoided.
US and Canada
Co-located statement
To comply with FCC RF exposure compliance requirement, the
antenna used for this transmitter must not be co-located or
operating in conjunction with any other transmitter/antenna except
those already approved in this filling.
Hand-held Devices
To comply with FCC RF exposure requirements, this device must
be operated in the hand with a minimum separation distance of 23
cm or more from a person's body. Other operating configurations
should be avoided.
Industry Canada Statement:
IMPORTANT NOTE:
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth
for an uncontrolled environment. This equipment should be
installed and operated with minimum distance 23cm between the
radiator and your body.
NOTE IMPORTANTE:
Déclaration d'exposition aux radiations:
Cet équipement est conforme aux limites d'exposition aux
rayonnements IC établies pour un environnement non contrôlé.
Cet équipement doit être installé et utilisé avec un minimum de 23
cm de distance entre la source de rayonnement et votre corps.
To satisfy FCC RF exposure requirements, a mobile transmitting
device must operate with a minimum separation distance of 23 cm
or more from a person's body.
LED Devices
LED Compliance Statement:
Classified as "EXEMPT RISK GROUP" according to IEC
62471:2006 and EN 62471:2008
Pulse duration: xx ms
Power Supply
Use ONLY a Symbol approved UL LISTED ITE (IEC/EN 60950-1,
LPS) power supply with electrical ratings: Output 5Vdc, min 1.2A,
with a maximum ambient temperature of at least 50 degrees C.
Use of alternative power supply will invalidate any approvals given
to this unit and may be dangerous.
Batteries
Taiwan - Recycling
EPA (Environmental Protection Administration)
requires dry battery producing or importing firms
in accordance with Article 15 of the Waste
Disposal Act are required to indicate the recycling
marks on the batteries used in sales, giveaway or promotion. Contact a
qualified Taiwanese recycler for proper battery disposal.
Battery Information
Use only Symbol approved batteries. Accessories which have
battery charging capability are approved for use with the following
battery models:
Symbol 82-172087-01 (3.7Vdc, 4410 mAh)
Symbol rechargeable battery packs are designed and constructed
to the highest standards within the industry.
However, there are limitations to how long a battery can operate or
be stored before needing replacement. Many factors affect the
actual life cycle of a battery pack, such as heat, cold, harsh
environmental conditions and severe drops.
When batteries are stored over six (6) months, some irreversible
deterioration in overall battery quality may occur. Store batteries at
half of full charge in a dry, cool place, removed from the equipment
to prevent loss of capacity, rusting of metallic parts and electrolyte
leakage. When storing batteries for one year or longer, the charge
level should be verified at least once a year and charged to half of
full charge.
Replace the battery when a significant loss of run time is detected.
Standard warranty period for all Symbol batteries is 30 days,
regardless if the battery was purchased separately or included as
part of the mobile computer or bar code scanner. For more
information on Symbol batteries, please visit:
https://atgsupportcentral.motorolasolutions.com/content/emb/
docs/MCS/batbasics1.pdf.
Battery Safety Guidelines
The area in which the units are charged should be clear of
debris and combustible materials or chemicals. Particular care
should be taken where the device is charged in a non
commercial environment.
Follow battery usage, storage, and charging guidelines found in
the user's guide.
Improper battery use may result in a fire, explosion, or other
hazard.
To charge the mobile device battery, the battery and charger
temperatures must be between +32 ºF and +104 ºF (0 ºC and
+40 ºC)
Do not use incompatible batteries and chargers. Use of an
incompatible battery or charger may present a risk of fire,
explosion, leakage, or other hazard. If you have any questions
about the compatibility of a battery or a charger, contact
Symbol support.
For devices that utilize a USB port as a charging source, the
device shall only be connected to products that bear the USB-
IF logo or have completed the USB-IF compliance program.
Do not disassemble or open, crush, bend or deform, puncture,
or shred.
Severe impact from dropping any battery-operated device on a
hard surface could cause the battery to overheat.
Do not short circuit a battery or allow metallic or conductive
objects to contact the battery terminals.
Do not modify or remanufacture, attempt to insert foreign
objects into the battery, immerse or expose to water or other
liquids, or expose to fire, explosion, or other hazard.
Do not leave or store the equipment in or near areas that might
get very hot, such as in a parked vehicle or near a radiator or
other heat source. Do not place battery into a microwave oven
or dryer.
Battery usage by children should be supervised.
Please follow local regulations to promptly dispose of used re-
chargeable batteries.
Do not dispose of batteries in fire.
Seek medical advice immediately if a battery has been
swallowed.
In the event of a battery leak, do not allow the liquid to come in
contact with the skin or eyes. If contact has been made, wash
the affected area with large amounts of water and seek medical
advice.
If you suspect damage to your equipment or battery, contact
Symbol support to arrange for inspection.
Radio Frequency Interference Requirements-FCC
Note: This equipment has been
tested and found to comply with the
limits for a Class B digital device,
pursuant to Part 15 of the FCC
rules. These limits are designed to
provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected
Consult the dealer or an experienced radio/TV technician for
help.
Radio Transmitters (Part 15)
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause
undesired operation.
Radio Frequency Interference Requirements -
Canada
CAN ICES-3 (B)/NMB-3(B)
This device is in compliance with the NRC for Industry Canada
applicable to license-exempt radios. Use is allowed with the
following two conditions: (1) the device must not produce
interference, and (2) the device must accept any interference to
the radio, even if the interference is likely to compromise
operation.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes: (1) l'appareil ne doit
pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage
est susceptible d'en compromettre le fonctionnement.
Label Marking: The Term "IC:" before the radio certification only
signifies that Industry Canada technical specifications were met.
Bluetooth® Wireless Technology for use through the EEA has the
following restrictions:
Maximum radiated transmit power of 100mW EIRP in the
frequency range 2.400 -2.4835 GHz.
RFID devices for use through the EEA have the following
restrictions:
Maximum radiated transmit power of 2W ERP in the frequency
range 865.6-867.6MHz
The use of RFID Devices has varying restrictions for use within the
EEA; please refer to the Zebra Declaration of Conformity (DoC) for
details at: http://www.zebra.com/doc.
Statement of Compliance
Symbol hereby declares that this device is in compliance with the
essential requirements and other relevant provisions of Directive
1999/5/EC and 2011/65/EU. A Declaration of Conformity may be
obtained from: http://www.zebra.com/doc.
Operation of the device without regulatory approval is illegal.
CAUTION In order to avoid or minimize the potential risk of
ergonomic injury follow the recommendations
below. Consult with your local Health & Safety
Manager to ensure that you are adhering to your
company’s safety programs to prevent employee
injury.
Warnings for Use of Wireless Devices
Safety in Hospitals
RF Exposure Guidelines
CAUTION Risk of explosion if battery is replaced by an
incorrect type.
Dispose of batteries according to instructions.
Marking and European Economic Area (EEA)

Other manuals for Zebra RFD8500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra RFD8500 and is the answer not in the manual?

Zebra RFD8500 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor type-
Scanner type1D/2D
Read rate (max)600 reads/s
Bluetooth version2.1+EDR
Operating frequency865 - 868 MHz
Standard interfacesBluetooth
Product colorGray
LED indicatorsYes
Protection featuresDust resistant, Splash proof
Battery capacity4410 mAh
Power source typeBattery
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-10 - 40 °C
Operating relative humidity (H-H)5 - 85 %
Mobile operating systems supportedAndroid 4.4, Android 5.0, Android 5.1, iOS 8.0, iOS 8.2, iOS 9.0
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth130 mm
Width185 mm
Height80 mm
Weight430 g

Related product manuals