The suction power may be adjusted during operation.
The recommended settings are:
Setting 1 – vacuuming curtains
Setting 2 – vacuuming upholstery
Setting 3 – cost-effective power
Setting 4 – vacuuming carpets
Setting 5 – vacuuming hard oors and crevices.
11
The vacuum cleaner type 5500.3 is additionally equipped
with remote suction power control located in the suction hose
handle. It allows to change the suction power without the
necessity to bend down.
In order to use this function, open the battery compartment
in the suction hose handle and insert two 1.5 V AAA type
batteries or two chargeable 1.2 V AAA type batteries.
ATTENTION! Insert the batteries so that the battery
pole marked market“+” is always directed towards the
lock of the compartment marked with “+”.
Use only high quality batteries. Battery leakage may
cause damage to the electronic system.
12
To use the remote control of the suction power press the
appropriate button on the hose handle ( , ):
To increase the suction power by one setting press the –
button .
To decrease the suction power by one setting press the –
button .
13
Press the button on the hose handle to temporarily
switch off the appliance and to operate in the STANDBY
mode.
To continue vacuuming press the STANDBY button (18) once
again. The appliance will start operating with the previously
set suction power.
ATTENTION! The infrared transmitter and receiver have
to “see” each other in order for the remote control
system to work properly.
14
The vacuum cleaner is equipped with accessories
compartment. In order to open the compartment pull up the
cover of the accessories compartment (16).
15
The accessories may be attached to the accessory
holder in the suction hose handle. This way they will be
available for use at any time.
16
The vacuum cleaner is equipped with the “Parksystem”
function. This function allows to temporarily switch off the
vacuum cleaner using the fastening hook of the combination
brush without the necessity to use the on/off button. In order
to do so, during operation insert the fastening hook of the
combination brush in the combination brush fastening (4).
The vacuum cleaner will automatically switch off.
Filter disassembly
This vacuum cleaner is equipped with a lter attachment with
cyclonic ltration that allows the vacuum cleaning without
conventional dust bag. The characteristic feature of cyclonic
lter is that occurrence of air-stream rotation is applied to
separation of solid pollutants. The separation of pollutants
is performed inside the part of circular section container,
in which the rotating air rejects the pollutants towards
container’s wall and then the pollutants are being removed
to neighboring container chamber through the outlet. The
initially cleaned air is directed towards cone shaped lter
HEPA, which holds the smallest dust fractions. The lter
HEPA is equipped with grid cover reducing pollutants
sedimentation on the lter’s active surface, wherethrough the
life time of HEPA lter can be extended.
The basic lter HEPA (High Efciency Particulate Air) class
H washable is located at the outlet of cyclone lter container.
In the HEPA washable lter there was a special ltering stuff
applied, this stuff allows to wash the dirty lter with running
water and then the lter can be reused.
At the vacuum cleaner outlet there is an exhaust lter HEPA
class H13 (non-washable) installed.
These lters have extremely high ltering capability, they
are made of special bers that can stop almost all dust
molecules. The H and H13 class denes the ltering
capability of given lter. The HEPA H lter stops 95,5% of
0,3 micron size molecules, and the H13 lter can stop even
99,95% of molecules.
Before changing the lters make sure that the vacuum
cleaner is switched off and unplugged from the mains
supply.
HEPA BASIC FILTER
It is necessary to clean periodically the basic lter HEPA to
remove small dust fractions.
Disassemble the dust container „CYKLON” and empty it
according to point (H).
1
Turn the basic lter HEPA (21) towards position UNLOCK
and remove it towards yourself.
2
Remove the basic lter protective grid (22).
Clean the grid, wash it and dry it accurately. In case of
●
grid damages replace it with a new one.
ATTENTION! Due to safety reasons it is disallowed to
put the wet protective grid.
Clean the creases of basic lter HEPA
●
(21). Filter can
be washed with running water. Dry the lter accurately.
In case of lter crease damage one should replace the
lter absolutely with a new one.
ATTENTION! Due to safety reasons putting neither the
wet nor damaged basic lter HEPA (21) is allowed.
3
When the grid and HEPA lter are cleaned and dried, put
the protective grid onto HEPA lter, then the complete set put
into dust container „CYKLON”.
4
Press the lock button and turn HEPA basic lter towards
LOCK position.
Put the dust container „CYKLON” together with installed
●
basic lter HEPA into the chamber of vacuum cleaner
and then close the cover until you hear the characteristic
sound („click”) according to point (H).
C
Downloaded From Vacuum-Manual.com Manuals