HOME AUTOMATION
Z02 - SWING GATE
PG13
Discovering the origin of the problem
1. Open control board
and check if it has
24V power supply
2. Check input fuses
3. Measure the 24V tran-
sformer’s output to detect
the locaon of the malfun-
con
4. If the motor works,
the problem is on the
control board. Pull it out
and send it to our ZERO
technical services for
diagnosis.
5. If the motor doesn’t
work, remove them
from installaon site
and send to our ZERO
technical services for
diagnosis.
Check all moon axis and associated moon systems related with the motor and the gate to nd out
what is the problem.
1. Turn o the cen-
tral’s motor and test it
directly connected to
a 24V baery to nd
the malfuncon.
2. If the engine operate,
the problem is in the cen-
tral. Pull it out and send it
to the ZERO technical ser-
vices for diagnosis
3. If the motors don’t work, remove them from in-
stallaon site and send to our ZERO technical servi-
ces for diagnosis
All ZERO control boards have LEDs that indicate the funconing of connecons to allow easy diagnosis
of faults. All safety devices LEDs (DS) in normal situaons remain On. All “START” circuits LEDs in normal
situaons remain O.
If LEDs devices are not all On, there is some security systems malfuncon (photocells, safety edges),
etc.
1 • Close with a shunt all safety systems on the control board (check manual of the control board in
queson). If the automated system starts working normally check for the problemac device.
2 • Remove one shunt at a me unl you nd the malfuncon device .
3 • Replace it for a funconal device and check if the motor works correctly with all the other devices. If
you nd another one defecve, follow the same steps unl you nd all the problems.
1. Turn o the cen-
tral’s motor and test it
directly connected to
a 24V baery to nd
the malfuncon.
2. If the engine operate,
the problem is in the cen-
tral. Pull it out and send it
to the ZERO technical ser-
vices for diagnosis
53 If this doesn’t work, remove control unit and
send it to ZERO technical services services.
Check all moon axis and associated moon systems related with the motor and the gate to nd out
what is the problem.
NOTE: Seng force of the controller should be sufcient to make the gate open and close without stop-
ping, but should stop and invert with a lile eort from a person. In case of safety systems failure, the gate
shall never cause physical damaged to obstacles (vehicles, people, etc.).