zero
HOME AUTOMATION
Z02 - SWING GATE
PG12
Problem Procedure Behavior Procedure II
Door doesn’t
work
Make sure you have 230V
power supply connected
to control board and if it
is working properly.
Sll not working.
Consult a qualied ZERO
technician.
Motor doesn’t
move but makes
noise
Unlock motor and move
the gate by hand to check
for mechani cal problems
on the movement
Encountered problems?
Consult an experienced
gate expert.
The gate moves easily?
Consult a qualied ZERO
technician.
Motor opens
but doesn’t
close
Unlock motor and move
the gate by hand to closed
posion.
Lock motor again and turn
o power supply for 5 se-
conds. Reconnect it and
send start signal using
transmier.
Gate opened but didn’t clo-
se again.
Check if there is any obsta-
cle in front of the photo-
cells;
Check if any of the control-
devices (key selector, push
buon, video intercom,
etc.) of the gate are jam-
med and sending perma-
nent signal to control unit;
Consult a qualied ZERO
technician.
Gate doesn’t
make complete
route
Unlock motor and move
ate by hand to check for
mechanical problems on
the gate
Encountered problems?
Consult an experienced
gate expert.
The gate moves easily?
Consult a qualied ZERO
technician.
05. TROUBLESHOOTING