ZXA10C320MaintenanceManual
Table2-9GTGOIndicatorDescription
IndicatorStatusDescription
LEDisOFF .ThecardisnotpoweredonorCPUisnotstarted.
GreenLEDashesslowly
everytwoseconds.
Thecardworksproperly.
GreenLEDisON.lThecardpassestheselftest,butfailsto
obtaindatafromtheswitchingandcontrol
cardorNMS.
lThecardisrunningthebootingprogram,or
isdownloadingasoftwareversionfromthe
switchingandcontrolcard.
lThecardcannotoperatebecausethereisno
legalsoftwareversion.
GreenLEDashesquickly.Thecardisdownloadingdata.
RedLEDisON.lAseriousfaultoccurstothehardwareofthe
card(suchas,thecardfailstopasstheself
test,orthesoftwareversionisincompatible
withthehardwareversion).
lTheNMSissendingarestartingcommand.
RedLEDashesslowly
everytwoseconds.
Thecardisinstalledinthewrongslot(different
fromthecongurationontheNMS).
RUN
YellowLEDashesslowly
everytwoseconds.
Thesoftwareversionofthecarddoesnotmatch
thatoftheswitchingandcontrolcard(auto-update
functionisnotconguredonthecard).Theservice
isproper.
LEDisOFF .lNoONUisconguredontheGPONinterface.
lTheGPONinterfacehasnoopticalmodule
installed.
lTheGPONinterfaceisshutdown.
lTheGPONinterfaceisTypeBprotectionport.
GreenLEDashes.TheGPONinterfaceandconnectedONUswork
properly.
ACTi(i=1–8)
RedLEDisON.TheGPONinterfacehasLossOfSignal(LOS)
alarms.
ETGO
Table2-10describestheindicatorsontheETGOpanel.
2-8
SJ-20120615152640-008|2012-06-30(R1.0)ZTEProprietaryandCondential