DescriptionConnector
Voltage measurement connector. For pin descriptions, see section Voltage measurement
connections (XU1, XU2) (page 18).
XU1
Voltage measurement connector. For pin descriptions, see section Voltage measurement
connections (XU1, XU2) (page 18).
XU2
Current measurement connector. For pin descriptions, see section Current measurement
connections (XIU, XIV, XIW) (page 19).
XIU
Current measurement connector. For pin descriptions, see section Current measurement
connections (XIU, XIV, XIW) (page 19).
XIV
Current measurement connector. For pin descriptions, see section Current measurement
connections (XIU, XIV, XIW) (page 19).
XIW
Fiber optic connectorV1R
Fiber optic connectorV1T
Power supply connector. For pin descriptions, see section Power supply connection
(XPOW) (page 19).
XPOW
LEDs
DescriptionColorLED
Power onGreenPOWER
Fiber optic link faultRedLINK FAULT
Input U2 voltage exceeds 60 VYellowU2 > 60 V
Input U1 voltage exceeds 60 VYellowU1 > 60 V
Settings
See the firmware manual of the appropriate control program for the firmware settings, eg,
selection between phase or main voltage measurement, etc.
There are no hardware settings on the measurement unit.
Hardware description 13