Referring Documents
Cable Factory Reset on NE810
It is possible to set the unit to factory default settings by using two straight standard
Ethernet RJ-45 cables.
1. Power of
f the switch and disconnect all Ethernet cables (copper and br
e).
2. Connect one Ethernet cable between Ethernet ports 3 and 10, and the other
between Ethernet ports 6 and 7.
The ports need to be connected directly by an
Ethernet cable, i.e., not through a hub or switch. Use a straight cable – not a
cross-over cable – when connecting the ports.
3. Power on the unit.
4.
Wait for the unit to start up. Ensure that the ON LED is ashing red.
The ON
LED ashing indicates that the unit is now ready to be reset to
factory default. Y
ou
now have the choice to go ahead with the factory reset, or to skip factory reset and
boot as normal.
Proceed with Factory Reset
Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet
cables. The ON LED will stop ashing. This initiates the factory reset process, and
after approximately 1 minute the unit will restart with factory default settings.
When the switch has booted up, the ON LED will show a green light, and is now
ready to use.