- 16 -
Power Cable Wiring
Total power for 8 cabinets with size 1152x288mm each is: 8x1.152x0.288x450w=1.2kw, arranged in 2x4
with 2 cabinet columns, and 4 cabinets for each column connected to power supply in series. In this case
use a 3X1.5mm
2
power cable to connect from the distribution box or socket to the bottom of the cabinet.
N Series User Manual
Network Cable Wiring
The network cable is connected from up to down in "S" shape. Please calculate the resolution as per
288x72 pixels for each cabinet, and connect signal cables in accordance with the Signal Sending Card’s
load range. Please note that the load pixel range for each network interface is not more than 650,000
pixels.
Power Cable
Signal Cable
Leading LED Applications
DVI or HDMI plug
USB plug
Laptop
Signal Sending Box