Step 7: Perform an Intra-Cell Handover
Example 1. Command Syntax:
CALL:TCHannel[:ARFCn][:SELected]:SEQ <numeric value>
OR
CALL:TCHannel[:ARFCn]:<PGSM|EGSM|DCS|PCS>:SEQ <numeric value>
Example 2. Programming Example:
The following example illustrates how to use these commands to perform an intra-cell handover.
! existing conditions: a mobile station is connected to the test
! set, operating mode is set to active cell and a call is in the
! connected state.
! Step 1: Change the traffic channel number
OUTPUT Test_set;”CALL:TCH:SEQ 65”!Starts process of handing over MS
!to new traffic channel 65.
!No other commands will be processed
!until this operation completes
!because the :SEQ has been attached.
! Step #2: Check that the call is still in the connected state. It
! is possible that the MS did not successfully connect on the
! new channel.
OUTPUT Test_set;”CALL:STAT:STAT?”
ENTER Test_set;Call_status$
IF Call_status$ <> “CONN” THEN
! <put error handler here>
END IF
! Call is connected so proceed with control program
Performing a Dual-Band Handover
A dual-band handover is accomplished using the CALL:TCHannel:BAND command. The recommended
process for performing a dual band handover is shown in the following figure.

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals