5 CALIBRATION
5.1 Detectorscalibration
Thewheelalignmentdetectorsarealreadycalibratedatthefactory;moreover,thecalibrationvaluesarestored
intheCPUmemoryofthedetectoritself.Therefore,wheninstallingorreplacingadetector,itisnotnecessary
tocalibrateorconfiguretheequipmentwithcalibrationdata.
The calibration is performed only in case of replacement of transducers or following ascertained repetitive
errors due to movements of transducers (consequently to falls, impactsetc.).Usethefollowingcalibration
systemsaccordingtothemodelssupplied:
1) STDA14calibrationsystem
Figure15
2) STDA14Ttransportablecalibrationsystem
Figure16
LegendFigure15,Figure16
A) Detectorfixingknobs
B) Spiritlevel
C) Standardcalibrationtool
D) Thickness3°forstandardcalibrationstand
E) Transportablecalibrationtool
F) Thickness3°fortransportablecalibrationstand