MULTIMODE
MONO
LEFT
RIGHT
STAGE MONITOR
STAGE MONITOR
1
3
2
4
EFFECTS
groups
(aux 1-4)
aux 5, 6
return 1, 2
insert
L-M-R Front-of-House system with 4 dedicated stage monitor sends.
COMPRESSOR/LIMITERS
To tune out stage resonances to prevent
acoustic feedback. These may
alternatively be positioned on stage in
series with the amplifier feeds for
performer control.
EQUALISERS
Signal processors such as these are
useful to prevent excessive peaks
overloading the amplification system.
up
up
down
These switches are
recessed to avoid
accidental operation. Set
using a pen tip or pointed
object.
Set the group 1-4 REV
switches to the down
position to route the aux
mix through the main
outputs to provide 4 stage
monitor sends.
Set the L and R REV
switches to the up position
for L-R F.O.H. feeds
Set the MONITOR MODE
switch to the up position
for mono out (L+R sum)
pre
post
This example shows the GL2 configured to
control a Left, Centre, Right Front-of House
system with 4 full feature stage monitor
sends.
Aux 1-4 are set pre-fade for the monitor
sends so that the send level is not affected by
the F.O.H. mix.
Aux 5 and 6 are set post-fade to access two
effects devices whose outputs are added to
the L-R mix via return inputs 1 and 2.
Alternatively these may be returned via the
channels, useful for stereo effects devices.
The channel and output inserts may be used
for floating effects and signal processing
devices such as compressors, limiters and
graphic equalisers.
inserts