EasyManuals Logo
Home>Allen-Bradley>Controller>SMC-3 150-CF147

Allen-Bradley SMC-3 150-CF147 User Manual

Allen-Bradley SMC-3 150-CF147
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
3 1023309
24
SMC-3
TM
(43 - 85 A)
INSTALLATION INSTRUCTION SHEET
1 1002344
2 1003429
41053-248
OF
N/A
N/A
N/A
REVISION
AUTHORIZATION
DR.
CHKD.
APPD.
DATE
DATE
DATE
E - DOC
LOCATION: MILWAUKEE, WISCONSIN U.S.A.
B-vertical.ai
DWG.
SIZE
SHEET
B
1234 56 78
A
B
C
D
E
F
G
H
REFERENCE
DIMENSIONS APPLY BEFORE
SURFACE TREATMENT
(DIMENSIONS IN INCHES)
TOLERANCES UNLESS
OTHERWISE SPECIFIED
.XX:
.XXX:
ANGLES:
41053
------------ ---------
---------
---------
------------
------------
(2)
THIS DRAWING IS THE PROPERTY OF
ROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,
USED OR DISCLOSED FOR ANY PURPOSE
EXCEPT AS AUTHORIZED IN WRITING BY
ROCKWELL AUTOMATION, INC.
Sequence
Dip
Switch
Number
Settings Current Limit Soft Start
Settings
Current Limit Start
Current Limit
I
S
Up to
Speed
Normal
t
2
t
1
U
s
U
e
U
e
Up to
Speed
Normal
t
3
t
2
t
1
U
s
U
e
t
3
Ie
I
S
U
s
U
e
U
s
U
e
t
1
Ie
I
S
t
1
t
2
t
1
I
e
I
s
I
k
1
2
3
4
5
6
7
3
3
Soft Start
(3)
(4, 5)
(9, 10)
(1, 2, 8)
(6, 7)
(14)
(14)
(11,12)
(13)
(16)
150%
250%
350%
450%
45
45
45
45
Start Time
2
5
10
15
12
12
12
12
8
8
8
8
8
8
8
20
25
12
12
30
12
t
1
(sec)
Start Time
2
5
10
15
12
12
12
12
8
8
8
8
8
8
8
20
25
12
12
30
12
t
1
(sec)
Kick Start
I
k
= 450% FLA
t
2
(sec)
Off
0.5
1.0
1.5
910
910
910
910
Kick Start t
2
(sec)
Off
0.5
1.0
1.5
910
910
910
910
Soft Stop
Off
1 x t
1
2 x t
1
3 x t
1
67
67
67
67
t
3
(sec) Soft Stop
Off
1 x t
1
2 x t
1
3 x t
1
67
67
67
67
t
3
(sec)
Aux. #1
Normal
Up To
Speed
Normal
Up To
Speed
Optional Aux. #2
14
14
14
14
Overload (OVLD)
Trip
Class
Trip
Class
Trip
Class
Trip
Class
OFF 10 15 20
11 12
11 12
11 12
11 12
Overload (OVLD) Reset
Manual
Auto
13
13
Phase Rotation
Enabled
Disabled
16
16
(%FLA)
Initial Torque
U
S
15%
25%
35%
65%
45
45
45
45
(%LRT)
t
1
Aux. #1
Normal
Up To
Speed
Up To
Speed
Normal
Optional Aux. #2
14
14
14
14
Enabled - No Fault
Disabled- No Fault
1 L1 3 L2 5 L3
ABC
Enabled - Fault
Disabled- No Fault
1 L1 3 L2 5 L3
ABC
97 - 98
Fault Push to Reset
A1 - A2
Fault Contact (97, 98)
9
Set Motor FLA
(15)
8
Delta
Line
Line or Delta
15
15
M
3~
2 / T1 4 / T2 6 / T310 / T58 / T412 / T6
M
2 / T1 4 / T2 6 / T3
Line Delta

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley SMC-3 150-CF147 and is the answer not in the manual?

Allen-Bradley SMC-3 150-CF147 Specifications

General IconGeneral
BrandAllen-Bradley
ModelSMC-3 150-CF147
CategoryController
LanguageEnglish

Related product manuals