48
NOTE:
- For any details concerning the valve adjustment, see the section 4.4.3. Valve offset
adjusting.
- Be sure the air inlet filter (9) and the exit of the gas valve pressure test point pipe (6)
are totally clean (if necessary clean them properly).
ATTENTION!: Each replacing of the gas valve is necessary to make the wizard test
(see the section 4.4.1), check the combustion and even the gas valve offset adjusting.
4.2.2. Mixer
NOTES:
-
Check that the combustion air filter is always clean and not clogged.
-
Check that the draft air tube is free of cuts or tears and that the clamps are tight
-
Check the connections tightness; do not use flames on gas burner because they
could be sucked into the mixing circuit and cause fire / explosion.