EasyManuals Logo
Home>Angelo Po>Oven>FX61E3

Angelo Po FX61E3 User Manual

Angelo Po FX61E3
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
Copyright by Servizio Clienti ANGELO PO Spa
48
NOTE:
- For any details concerning the valve adjustment, see the section 4.4.3. Valve offset
adjusting.
- Be sure the air inlet filter (9) and the exit of the gas valve pressure test point pipe (6)
are totally clean (if necessary clean them properly).
ATTENTION!: Each replacing of the gas valve is necessary to make the wizard test
(see the section 4.4.1), check the combustion and even the gas valve offset adjusting.
4.2.2. Mixer
NOTES:
-
Check that the combustion air filter is always clean and not clogged.
-
Check that the draft air tube is free of cuts or tears and that the clamps are tight
-
Check the connections tightness; do not use flames on gas burner because they
could be sucked into the mixing circuit and cause fire / explosion.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Angelo Po FX61E3 and is the answer not in the manual?

Angelo Po FX61E3 Specifications

General IconGeneral
BrandAngelo Po
ModelFX61E3
CategoryOven
LanguageEnglish

Related product manuals