EasyManuals Logo
Home>ANSI>Safety Equipment>FRONTLINE RPA061S

ANSI FRONTLINE RPA061S User Manual

Default Icon
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Manual Revision Code: FRONTLINE-SRL-04 10-19-20
6
Body Support:
A full body harness must be worn when using SRL. Connect the SRL to the user's harness shoulder straps
the back (dorsal) D-ring.
Be noted that the Dual SRLs are connected by the dual connector. When connecng it to harness, the
connector should be connected on the web loop of the back harness not on the D-ring.
Frontline friendly reminder-
Do not use a body belt for free fall applicans. Per OSHA 1926.502 requirement.
Making Connecons:
Snap hooks and carabiners used with this equipment must be self-locking. Ensure all connecns are
compable in size, shape, and strength. Do not use equipment that is not compable. Ensure all connectors
are fully closed and locked, ensure unintended disengagement cannot occur.
Frontline connectors (snap hooks and carabiners) are designed to be used only as specied in each
products users instrucn.
Inspecon:
Before each use of this fall protecn equipment carefully inspect it to assure it is in good working
condin. Check for worn or damaged parts. Ensure all bolts are present and secure. Check that the lifeline
is retracng properly by pulling out the line and allowing it to slowly retract. If there is any hesitaon in
retracn, remove the SRL from service, mark " UNUSABLE". Inspect the lifeline for cuts, frays, burns,
crushing and corrosion. Check to lock acby pulling sharply on the line.
Product Life:
The funcnal life of SRL is determined by work condins and maintenance. As long as the SRL passes
inspecn criteria, it may remain in service.
Disposal:
Dispose of SRL if it has been subjected to fall arrest forces or inspection reveals an unsafe or defecve
condin. Before disposing of the SRL, cut the cable lifeline in half or otherwise disable the SRL to eliminate
the possibility of inadvertent reuse.
MAINTENANCE, SERVICING, AND STORAGE
Cleaning: Cleaning procedures for SRL are as follows:
Ensure the SRL is kept free of excess paint, grease, dirt or other contaminants as this may cause to cable or
retracng mechanism to malfuncn. Ensure no debris enters the housing through the cable access port.
Clean the exterior of the unit as required with a detergent/water solun. Do not allow water other

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ANSI FRONTLINE RPA061S and is the answer not in the manual?

ANSI FRONTLINE RPA061S Specifications