1
Thank you for choosing APEC reverse osmosis systems.
You now own the finest water filter in America.
Please read and become familiar with instructions and parts needed before proceeding with the
installation.
(This manual is constructed for standard APEC Ultimate RO System. For RO-PH90, RO-PERM and
RO-PUMP system installation, please refer to the included addendum.)
BEFORE INSTALLATION:
Inspect the system:
Please take the system and all the components out of the box. Inspect the system and all the
connection fittings carefully, make sure nothing is damaged during shipping. If any part is cracked
or broken, please do not proceed with the installation and contact APEC or your distributor for an
exchange or diagnosis.
Recommended tools list:
Variable speed drill
Drill bit: 1/4” (for the waste line), 1/8” (as pilot, not mandatory), and 1/2” (for standard
faucet hole, air-gap faucet requires 1&1/4” hole)
5/8”, 9/16” open-end wrench, or adjustable wrench, pliers
Phillips screwdriver
Utility knife, or scissors
Teflon tape
Operating Parameter
Operating pressure: 85psi maximum
Feed water temperature: 40 – 100 degree F (4-37 degree C)
Do not connect this unit to hot water source
Install the RO in a sheltered environment, avoid exposure to hot and cold weather or under
direct sun light.
Copyright:
This manual is copyrighted by APEC Inc. Under the copyright laws, this manual may not be reproduced in any form, in
whole or part, without the prior written consent of APEC Inc. Manual print ver. 3.2, 2015 Jul.
General Installation/Operation/Maintenance Requirements
Installation needs to comply with state and local laws and regulations.
System must be installed indoor away from possible environmental damage
Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after system. Systems certified for cyst reduction may be
used on disinfected water that may contain filterable cysts.
This reverse osmosis system contains a replaceable treatment component critical for
effective reduction of total dissolved solids. The product water shall be tested periodically to
verify that system is performing satisfactorily.