FOR MODELS: JGW, JGR AND JGJ SECTION 3 - START UP
1/01 PAGE 3 - 3
Compressor Model ______________________ Serial No. F-______________________
YES NO
12. Have piston end clearances been checked with feeler gauges? _____ _____
Record below:
Throw #1 #2 #3 #4 #5 #6
HE_______ _______ _______ _______ _______ _______
CE_______ _______ _______ _______ _______ _______
13. Has the crankcase been filled with oil to the proper level? _____ ______
14. Has proper oil been installed if extreme ambient conditions
exist or special gases are compressed? _____ ______
15. Is the compressor crankcase oil level control working and
set at the proper level? _____ ______
16. Is the crankcase oil supply isolation valve open? _____ ______
17. Does the crankcase low level shutdown work? _____ ______
18. Have the recommended oil filter elements been installed? _____ ______
19. Are the oil filter element and all lube oil piping primed with oil? _____ ______
20. Is the low oil pressure shutdown installed and tubed correctly
to the downstream side of the oil filter? _____ ______
21. Does the low oil pressure shutdown work? _____ ______
22. Oil cooler? Compressor inlet oil temperature is 190°F (88°C) max. _____ ______
23. Is the crankcase oil temperature shutdown installed, set
and working? _____ ______
24. If oil is cooled, is there a temperature control valve? _____ ______
25. Is the crankcase breather element clean? _____ ______
26. Is the force feed lubricator box filled with oil? _____ ______
27. Is the force feed lubrication system primed? _____ ______
28. Is the force feed lubrication system no flow shutdown
installed and working? _____ ______
29. Is the force feed blow out assembly installed? Check rupture
disc for color? Purple is standard = 3250 PSIG (22 400 kPa). _____ ______
30. Has the lubricator instruction plate or Technical Manual Cylinder
Lubrication Sheet been checked for proper lube feed rate? _____ ______
31. Is there a working vibration shutdown mounted on compressor? _____ ______
32. Are the primary and secondary packing vents and the distance
piece vents open, and when necessary, tubed off of the skid or
out of the building? _____ ______
33. Is there some method of suction pressure control? _____ ______
34. Are the suction pressure, interstage pressure and discharge
pressure shutdowns set and working? _____ ______
35. Are the safety relief valves installed and working to protect
cylinders and piping for each stage of compression? _____ ______