4.
COMMISSIONING
The
thermostat{s)
on
the
immersion
heater(s)
should
be
adjusted
to
trip
at
eo-es^C.
This
is
the
ideal
temperature
to
prolong
element
life
in
hard
water
areas.
Scale
on
the
sheath
builds
up
more
rapidly
at
temperatures
above
this
causing
the
element
to
overheat
and
premature
failure
can
occur.
Higher
temperatures
without
additional
controls
would
result
in
scalding.
In
known
hard
water
areas
the
use
of
a
scale
inhibitor
is
also
recommended.
In
addition
to
the
thermostat
the
thermal
cut-out
will
switch
power
off
to
the
element
should
the
thermostat
malfunction,
causing
an
excessive
rise
in
water
temperature.
The
thermal
cut-out
can
be
reset
manually
after
the
fault
has
been
corrected.
INDIRECT
SYSTEMS
For
models
up
to
300
litres
a
mains
supply
of
240V,
3kW
(13
amps)
will
be
required
for
the
direct
immersion
heater,
heat
resistant
cable,
round
3
core
2.5mm2
(to
BS6141)
must
be
used.
For
High
Capacity
500
litre
models
consult
the
wiring
diagram
on
the
reverse
of
the
inspection
panel.
For
indirect
controls
a
240V,
3
amp
supply
Is
required.
The
cables
must
be
clamped
in
position
(as
previously
stated)
and
the
control
thermostat
should
be
set
at
60°C
for
the
reasons
above.
In
addition
to
the
thermostat
there
is
a
thermal
cut-out
should
the
thermostat
fail.
Refer
to
Fig.
3.14.
WARNING
:
THE
APPLIANCE
MUST
BE
EARTHED.
The
earth
continuity
conductor
of
the
electrical
installation
must
be
effectively
connected
to
all
exposed
parts
of
other
appliances
and
services
in
the
room
in
which
the
water
heater
is
to
be
installed
and
conform
to
the
I.E.E.
wiring
regulations.
Note:
Do
not
switch
on
the
immersion
heater
or
fire
the
boiler
until
the
cylinder
is
full
of
water.
Check
for
obvious
signs
of
damage
to
the
cylinder
and
controls,
and
also
that
the
controls
fitted
correspond
with
the
references
quoted
in
these
instructions.
Ensure
that
the
drain
cock
at
the
base
of
the
appliance
is
closed
before
commencing.
1)
ProTech
Models
Only.
Ensure
that
the
ProTech
anti-corrosion
system
is
connected
to
the
electrical
supply;
2)
Ensure
that
the
line
strainer
(situated
in
the
pressure
reducing
valve)
is
clear
of
installation
debris
and
clean
If
necessary;
3)
Check
that
the
pressure
in
the
expansion
vessel
is
the
same
as
the
incoming
water
pressure;
4)
Open
all
outlet
taps;
5)
Turn
on
mains
water
supply
and
allovy
the
water
heater
to
fill;
6)
Ensure
that
the
hot
water
system
is
flushed
in
accordance
with
BS
6700;
7)
Close
taps
in
turn
after
having
purged
the
system
of
air;
8)
Check
for
leaks
around
the
controls
and
immersion
heaters
and
again
after
the
unit
has
heated
up;
9)
Check
that
no
water
is
passing
to
waste
through
the
relief
valves;

Other manuals for Ariston ST 100 ProTech

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston ST 100 ProTech and is the answer not in the manual?

Ariston ST 100 ProTech Specifications

General IconGeneral
BrandAriston
ModelST 100 ProTech
CategoryWater Heater
LanguageEnglish

Related product manuals