2.
GENERAL
INFORMATION
2.1
Guarantee
This
manual
is
an
integral
and
essential
part
of
the
product.
It
should
be
kept
with
the
appliance
so
that
it
can
be
consulted
by
the
user
and/or
authorised
personnel.
Please
read
carefully
the
instructions
and
notices
about
the
appliance
contained
in
this
manual,
as
they
provide
important
information
regarding
the
safe
installation,
use
and
maintenance
of
the
cylinder.
Failure
to
do
so
may
invalidate
the
guarantee.
When
installing
and
servicing
the
cylinder,
Ariston
ThermoUK
Ltd
recommend
the
use
of
protective
clothing
i.e.
gloves.
The
Ariston
range
of
unvented
cylinders
come
with
Varying
guarantees
depending
on
the
model
of
cylinder.
The
guarantee
periods
offered
with
each
model
of
cylinder
are
as
follows:
ST
Range
Classico
HE
Range
Primo
HE
Range
10
Years
tank
2
Years
electrical
components
5
Years
tank
2
Years
electrical
components
25
Years
tank
2
Years
electrical
components
Note:
The
guarantee
is
subject
to
the
cylinder
being
installed
and
serviced
annually
by
a
competent
person
as
per
the
servicing
instructions
in
Section
5.6
of
this
manual.
For
units
with
the
ProTech
anti-corrosion
device
it
must
be
ensured
that
this
is
connected
and
operating
correctly
(green
LED
only).
2.2
How
THE
Appliance
Works
The
immersion
heater(s)
are
controlled
through
a
thermostat
which
senses
the
water
temperature.
The
operating
temperature
can
be
pre-set
by
adjusting
the
spindle
in
the
head
of
the
thermostat.
In
addition
to
the
thermostat
there
is
a
thermal
cut-out
incorporated
if
the
thermostat
fails
and
the
water
temperature
rises
too
high.
Once
the
cut-out
operates
it
can
only
be
re-set
manually
after
the
fault
has
been
rectified.
Indirect
models
have
dual
thermal
controls.
In
addition
to
the
above
there
is
a
separate
cylinder
thermostat
and
thermal
cut-out
for
controlling
each
indirect
circuit.
Again
the
thermal
cut-out
operates
if
the
cylinder
thermostat
fails,
by
disconnecting
the
live
feed
(call
for
hot
water)
from
the
programmer.
ITI/ITD/ITSI
models
have
a
stainless
steel
tank
and
therefore
need
no
protection
against
corrosion.
STD/STI
models
have
an
enamelled
steel
tank
and
therefore
are
supplied
with
magnesium
anodes
to
prevent
corrosion
of
the
cylinder
tank.
It
is
imperative
that
the
top
anode
is
checked
during
the
annual
service
and
if
found
to
be
corroded
both
anodes
should
be
replaced.
Failure
to
do
so
could
invalidate
the
warranty
of
the
tank.
i-.
^
The
Wall-hung
(ST)
units
utilise
the
ProTech
anti-corrosion
system
(electronic
anode).
This
prevents
an
electrolytic
reaction
between
the
tank
and
dissimilar
metals.
The
ProTech
system
shows
if
it
is
operating
correctly
(green
LED)
or
incorrectly
(red
LED).
In
the
event
that
the
red
LED
lights
(even
with
the
green
light
still
showing),
it
is
imperative
that
a
service
agent
is
contacted
immediately
as
continued
use
with
the
ProTech
system
in
this
state
could
invalidate
the
warranty
on
the
tiank.
The
factory
fitted
temperature
&
pressure
relief
valve
at
the
top
of
the
cylinder
is
a
safety
device
to
back-up
the
thermostat(s)
and
thermal
cut-
out(s).
It
works
by
sensing
an
excess
in
water
temperature
or
pressure
and

Other manuals for Ariston ST 100 ProTech

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston ST 100 ProTech and is the answer not in the manual?

Ariston ST 100 ProTech Specifications

General IconGeneral
BrandAriston
ModelST 100 ProTech
CategoryWater Heater
LanguageEnglish

Related product manuals