D6001DE-R Double Unit Series (Double Egress) Power Operator
Contents
Certications and Standards...............................................................................2
Product Safety Warnings ..................................................................................2
General Information.......................................................................................3
Before You Begin ..........................................................................................4
Mounting Hardware Chart.................................................................................4
Technical Data ............................................................................................4
Prepare Frame and Doors..................................................................................5
Install Operators ..........................................................................................8
Install Track and Arm (Left Door) .........................................................................11
Install Arms (Right Door) .................................................................................12
Adjustments .............................................................................................13
Power Operators .........................................................................................14
Sync Operators...........................................................................................15
Finalize Installation.......................................................................................16
General Electrical Information ............................................................................16
Wiring Options...........................................................................................17
Troubleshooting .........................................................................................28
D6001DE-R Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Certications and Standards
• ETL Certied: Operator conforms to ANSI/UL standard 325 for automatic closing doors and UL10C Positive Pressure
Fire Test for Door Assemblies.
• ANSI A156.19: These products are designed to conform to this specication “for power assist and low energy power
operated doors.” These products are designed to exceed all the requirements for “Low Energy Power Operated Door”.
• Americans with Disabilities Act (A.D.A.): These door operators can be installed and adjusted to conform with A.D.A.
regulations.
• ANSI A117.1: These door controls permit door assemblies to conform to the requirements of this specication “for
buildings and facilities - providing accessibility and usability for physically handicap people”.
WARNING: To reduce risk of injury to person, use this operator only with Pedestrian Swing doors. FOR INDOOR USE ONLY
Product Safety Warnings
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Install only on a properly operating and balanced door.
A door that is operating improperly could cause severe
injury. Have qualied service personnel make repairs to any
hardware before installing the operator.
3. Remove, or make inoperative, all locks (unless mechanically
and/or electrically interlocked to the power unit) that are
connected to the door before installing the operator.
4. Do not connect the door operator to the source power
until instructed to do so.
5. Never let children operate or play with door controls. Keep
remote control (when provided) away from children.
6. Personnel should keep away from a moving door in
motion.
7. Test door’s features at least once a month. After
adjusting either force or limit of travel, retest door
operator’s features. Failure to adjust operator
properly may cause severe injury or death.
8. KEEP DOOR PROPERLY OPERATING. An improperly
operating door could cause severe injury or death.