ATAG A-Serie
24
The pump is preset in the factory to automatic. This
means that the pump is switched on when there is
a request for heating or hot water. If necessary, the
pump can also operate continuously. This requires
the following actions:
Press the OK key for 3 seconds.
The display is showing ‘P6 (alternated with) 81’;
Press the Scroll key 1x;
The display is showing ‘P6 (alternated with) 84’;
Press the OK key;
The display is showing ‘b0’;
Press the OK key;
The display is showing ‘off (= automatic);
Adjust the value by means of the + or - key to
‘on’ (= continuously);
Briey press the OK key to conrm the new
setting.
The display is showing the chosen parameter
again
Press the ESC key until the default display is
shown again.
An arrow appears on the display in the bottom
left-hand corner, indicating that the pump is now
continuously switched on.
If during 8 minutes no key has been pressed,
the default display is displayed on the screen
automatically.
ba
r
In case of frost you are
advised to have the
circulation pump run
continuously to reduce the
chance of frozen pipes.
8 Pump continuous
OK
ESC
scroll

Other manuals for Atag A203C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atag A203C and is the answer not in the manual?

Atag A203C Specifications

General IconGeneral
Type-
Fuel typeNatural gas
Boiler systemCombi boiler system
Product colorWhite
Heater locationIndoor
Placement supportedVertical
Boiler type (NL label)HR
HR inspection label class107
Maximum power20000 W
Minimum power4400 W
Water flow (60 °C)6 l/min
Domestic Hot Water (DHW) flow10.7 l/min
Weight and Dimensions IconWeight and Dimensions
Depth395 mm
Width500 mm
Height650 mm
Weight37000 g

Related product manuals