ATAG A-Serie
17
Work on the installation should only be carried out
by qualied personnel with calibrated equipment.
When replacing parts, only ATAG Service
components may be used.
If you smell gas:
- No naked ames! No smoking!
- Do not switch lights on or off or use other
electrical switches.
- Do not use the phone
- Close the gas mains
- Open windows and doors
- Warn the occupants and leave the building
- Only call the gas company or installer once you
are outside the building.
Corrosion protection
Do not use sprays, chlorine-containing cleaning
products, solvents, paints etc. in the vicinity of the
device or its air supply. These substances have
an adverse impact on the device and can lead to
corrosion that may result in failures.
Checking the heating water
Regularly check the water pressure of the heating
installation
Always use potable water for lling the installation.
Adding chemical agents such as frost and
corrosion inhibitors are only to be added by your
installer.
If in doubt, check with your installer or ATAG
Heating UK Ltd (See contact details on page 25).
2 Safety

Other manuals for Atag A203C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atag A203C and is the answer not in the manual?

Atag A203C Specifications

General IconGeneral
Type-
Fuel typeNatural gas
Boiler systemCombi boiler system
Product colorWhite
Heater locationIndoor
Placement supportedVertical
Boiler type (NL label)HR
HR inspection label class107
Maximum power20000 W
Minimum power4400 W
Water flow (60 °C)6 l/min
Domestic Hot Water (DHW) flow10.7 l/min
Weight and Dimensions IconWeight and Dimensions
Depth395 mm
Width500 mm
Height650 mm
Weight37000 g