110
Instruction book
9096 3321 00
Procedure
7.4 Starting
Procedure
For the position of the air outlet valve and the drain connections, see sections Introduction
and Condensate system
Location of Unloader
56756F
See section Initial start-up for location of the oil system components.
Check oil level (Gl), top up if necessary. The pointer should be in the upper field of the
green range or in the orange range. If the pointer registers in the LOW range,
depressurize the oil system (see section Problem solving). Wait until the compressor
has depressurized. Unscrew oil filler plug (FC) only one turn to permit any pressure in
the system to escape. Remove the filler cap and add oil until the level reaches the filler
neck. Tighten the plug.
- If necessary, empty the dust trap of the filter, see section Air filter.
- If the red part of the air filter service indicator shows full out, replace the air filter
element. Reset the service indicator (VI) by pushing the knob in the extremity of the
body and reset the service warning. On compressors equipped with an ElektronikonĀ®
Graphic controller, see section Service menu.
On water-cooled compressors, also:
Check that the cooling water drain valves in the inlet and outlet pipes are closed.
Open the cooling water inlet valve.
Open the water flow regulating valve. This step can be skipped if, after previous
operation, the setting of this valve has not been changed.
-
-