8. Periodically check that:
All guards are in place and securely fastened
All hoses and/or pipes inside the machine are in good condition, secure
and not rubbing
There are no leaks
All fasteners are tight
All electrical leads are secure and in good order
Safety valves and other pressure relief devices are not obstructed by dirt
or paint
Air outlet valve and air net, i.e. pipes, couplings, manifolds, valves, hoses,
etc. are in good repair, free of wear or abuse
Electrical cabinet air cooling filters are not clogged
9. If warm cooling air from vacuum pumps is used in air heating systems, e.g. to
warm up a workroom, take precautions against air pollution and possible
contamination of the breathing air.
10. On water-cooled vacuum pumps using open circuit cooling towers, protective
measures must be taken to avoid the growth of harmful bacteria such as
Legionella pneumophila bacteria.
11. Do not remove any of, or tamper with, the sound-damping material.
12. Never remove or tamper with the safety devices, guards or insulations fitted
on the machine.
13. The oil separator tank can be slightly pressurized. Do not open and do not
leave oil filler or drain plugs open during operation.
14. Do not use the pump as a compressor.
15. Never run the pump without the air intake filter mounted.
Note:
Also consult Safety precautions during installation on page 9 and Safety
precautions during maintenance or repair on page
12
.
These precautions apply to machinery processing or consuming air or inert
gas. Processing of any other gas requires additional safety precautions typical
to the application which are not included herein.
Some precautions are general and cover several machine types and
equipment; hence some statements may not apply to your machine.
2.4.
Safety precautions during maintenance or repair
WARNING:
All responsibility for any damage or injury resulting from neglecting these
precautions, or non-observance of the normal caution and care required for
installation, operation, maintenance and repair, even if not expressly stated, will
be disclaimed by the manufacturer.
1. Always use the correct safety equipment (such as safety glasses, gloves,
safety shoes, etc.).
Important safety information
12/2021 - ©Atlas CopcoPage 126996022430_C

Other manuals for Atlas Copco GVS 60A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco GVS 60A and is the answer not in the manual?

Atlas Copco GVS 60A Specifications

General IconGeneral
BrandAtlas Copco
ModelGVS 60A
CategoryWater Pump
LanguageEnglish

Related product manuals