STOPPING
Press the stop button. Open the air outlet valves to
avoid that part of the system will remain pressurized.
After pressing the Stop button the display will show:
After cooling down the engine will stop and the
display will show
The engine is stopped, and the controller will do a
double check to see if the engine is really stopped.
SHUTDOWN
When the machine is shutdown due to a critical alarm
or an emergency stop the display will show
The ENTER button has to be pressed to acknowledge
the shown alarm and to be able to proceed.
Active Buttons
MAIN VIEW
ENGINE COOLING DOWN
1200RPM 6.0bar1286h
180s
84s
0s
40%
Active Buttons
MAIN VIEW
PURGING POWER OFF PREVENTION
--RPM 5.3bar1286h
40%
180s
74s
0s
Active Buttons
MAIN VIEW
SHUTDOWN
0.0
2000 EMERGENCY STOP