69
3-33 GS1 DataBar (GS1 DataBar Truncated)
GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format,
except its height is reduced to a 13 modules minimum; while GS1 DataBar should have a height greater
than or equal to 33 modules.
Read:
Format
16 Data digits
Code ID setting: Refer to Code ID setting of 3-15 UPC-A.
Insertion group selection: Refer to Insertion group selection of 3-15 UPC-A.
Conversion:
UCC/EAN 128- Refer to Code ID transmission of 3-43 String transmission, ]Cm will be identified as
AIM ID.
UPC-A or EAN-13- Barcode beginning with a single zero as the first digit has the leading 010
stripped and the barcode reported as EAN-13. Barcode beginning with two or more zeros but not six
zeros has the leading 0100 stripped and the barcode reported as UPC-A.
Multiple-scan setting
Single-scan setting
Option bar code
Option
Alpha. entry
Read
Disable
00
Enable
01*
*
Code ID setting
00-FF
16
(ASCII)
00-FF
16
<R>*
*
Insert group selection
00-66
00-66
00*
*
Conversion
None
00*
*
UCC/EAN 128
01
UPC-A or EAN-13
02

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Axon MICRELEC CS2600-BT and is the answer not in the manual?

Axon MICRELEC CS2600-BT Specifications

General IconGeneral
BrandAxon
ModelMICRELEC CS2600-BT
CategoryBarcode Reader
LanguageEnglish

Related product manuals