14
ENGLISH
6.7
REMARKS ON HEAT PUMP OPERATION
6.8
SIMPLIFIED DESCRIPTION OF CONTROL
This state is due to the following causes:
Activity
Remote device or control key
of heat pump
Display Heat pump response
Heat pump
Connect the supply cable plug
in the mains socket or switch
ON the circuit breaker of HP
supply circuit (in case of fi xed
connection;
Shows the current water
temperature.
HP) power ON
Switch the fi ltration
pump ON
dtto
Switching ON
the pool water
circulation in the
pipe system
Selectable within
the range of
15 °C to 45 °C
The HP heats or cools
water until achieving its
required temperature
Setting pool water
temperature
Press the key
The HP will be put into
operation within the time
interval of 1 – 3 min in its
previously set operating
mode (heating or cooling).
Heat pump
starting
Press the key
MODE
The HP will stop for 3 – 4
min, its mode changes and
the HP starts in the newly
set mode.
HEATING MODE
Insuffi cient water fl ow rate. Close the bypass
valve to increase heat transfer from water to water
COOLING MODE
Too high water fl ow rate. Open the bypass valve to reduce
water fl ow rate and increase thereby the heat transfer
from water to coolant.
Insuffi cient fl ow of air. Make sure that evaporator
lamellae are not fouled.
Note: This error message will be most possibly displayed when the temperatures both of pool water and of ambient air are high.
Heat pump effi ciency will increase with the increasing temperature of ambient air.
The achievement of required pool water temperature may take a few days. This time is quite normal and depends particularly on climatic
conditions, the volume of pool water, size of water surface area, time of heating pump operation and pool heat loss (caused by evaporation, heat
transfer through pool walls, radiation, etc.). Failing to take measures to limit the heat loss, it will not be economical, or even possible, to maintain
any higher temperature of pool water.
To limit the heat loss at the time in which the pool is out of use, a cover or solar blanket can be used.
The temperature of pool water should not exceed 30 °C. Warm water has not any refreshing eff ect and, moreover, creates favourable conditions for
microbial growth (of algae, etc.). In addition, certain pool components may have temperature limits, for instance the foils of foil pools can get soft
and lose their fi rm shape. Do not set any higher temperature than 30 °C on your thermostat.
MODE