1.0 Introduction – Page 4
B.S. Codes of Practice
1.1 Description
1. The Baxi Solo 2 PF is a gas fired room sealed fan
assisted central heating boiler with range rated outputs as
shown In the table below
2. Each appliance is preset at a MID RANGE heat input
rating and is designed for use on NATURAL GAS only.
3. All boilers are suitable for fully pumped open vented
central heating and domestic hot water systems and
sealed systems.
4. The appliance data badge is fitted to the combustion
box door.
1.2 Installation
1. The appliance is suitable for installation only in G.B.
and I.E. and should be installed in accordance with the
rules in force. For Ireland install in accordance with
I.S.813 “INSTALLATION OF GAS APPLIANCES”. The
installation must be carried out by a CORGI Registered
Installer or other competent person and be in accordance
with the relevant requirements of GAS SAFETY (Installation
and Use) REGULATIONS, the BUILDING REGULATIONS
(Scotland) (Consolidation), the LOCAL BUILDING
REGULATIONS, the CURRENT I.E.E. WIRING REGULATIONS
and the bye laws of the Local Water Undertaking. WHERE
no specific instructions are given, reference should be
made to the relevant BRITISH STANDARD CODES OF
PRACTICE.
2. All systems must be thoroughly flushed and
treated with inhibitor (see Section 3.1).
1.3 Important Information
STANDARD
B S. 6891
B S. 5546
B S. 5449
B S. 6798
B S. 5440: Pt 1
B S. 5440: Pt 2
SCOPE
Gas Installation
Installation of hot water supplies for
domestic purposes
Forced circulation hot water systems
Installation of gas fired hot water
boilers
Flues
Ventilation
This product contains Refractory Ceramic Fibres (R.C.F.)
which are man-made vitreous silicate fibres. Excessive
exposure to these materials may cause temporary
irritation to eyes, skin and respiratory tract. Care must be
taken when handling these articles to ensure the release
of dust or fibres is kept to a minimum.
To ensure that the release of fibres from these articles is
kept to a minimum, during installation and servicing it is
recommended that a H.E.P.A. filtered vacuum is used to
remove any dust, soot or other debris accumulated in and
around the appliance. This should be performed before
and after working on the installation.
It is recommended that any replaced item(s) are not
broken up but sealed within heavy duty polythene bags
and clearly labelled ‘R.C.F. waste”. This is not classified
as “hazardous waste” and may be disposed of at a tipping
site licensed for the disposal of industrial waste.
Protective clothing is not required when handling these
articles but it is recommended that gloves are worn and
the normal hygiene rules of not smoking, eating or
drinking in the work area are followed and always wash
hands before eating or drinking.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baxi Solo 2 50 PF and is the answer not in the manual?

Baxi Solo 2 50 PF Specifications

General IconGeneral
BrandBaxi
ModelSolo 2 50 PF
CategoryGas Heater
LanguageEnglish

Related product manuals