EasyManuals Logo
Home>Beckhoff>Servo Drives>AX5000 Series

Beckhoff AX5000 Series User Manual

Beckhoff AX5000 Series
49 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
4 Product description BECKHOFF Drive Technology
26 Version 6.2 AX5000
4.7.5 X04, X05 - EtherCAT connection
Terminal point
Connection
X04 (IN)
incoming EtherCAT line
X05 (OUT)
outgoing EtherCAT line
4.7.6 X06 – Digital I/Os
CAUTION
Destruction of the AX5000!
This connector is not designed for external power supply. It is supplied via
the 24 V supply (U
p
) of connector X03.
Note
Output current
The specified output currents are maximum values. The actual values
depend on your current configuration.
Terminal point
Connection
Output current
24
Output voltage (U
p
24 V
DC
+)
1 A max.
0
Input 0
1
Input 1
2
Input 2
3
Input 3
4
Input 4
5
Input 5
6
Input 6
7
Input 7 or output (configurable) (U
p
24 V
DC
+)
0.5 A max.
0 V
Output voltage GND (-)

Table of Contents

Other manuals for Beckhoff AX5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beckhoff AX5000 Series and is the answer not in the manual?

Beckhoff AX5000 Series Specifications

General IconGeneral
BrandBeckhoff
ModelAX5000 Series
CategoryServo Drives
LanguageEnglish

Related product manuals