Page #45 background imageLoading...
Page #45 background image
Mounting and wiring
Note
Changing the interface parameters
If other parameters are required than the set parameters, please order the required config-
uration:
- CX51x0-N031-0001 RS485 with echo, end point (with termination)
- CX51x0-N031-0002 RS485 without echo, stub (without termination)
- CX51x0-N031-0003 RS485 with echo, stub (without termination)
- CX51x0-N031-0004 RS422 full duplex end point (with termination)
Note
Driver support for interface
The manufacturer of the driver does not support all the standard features of the interface.
This means that some applications cannot be run without problems under Windows.
The following APIs and IOCTLs are not supported.
SetupComm
SetupComm
ClearCommBreak
EscapeCommFunction (no support for parameter set to SETBREAK and CLRBREAK)
IOCTL_SERIAL_XOFF_COUNTER
IOCTL_SERIAL_LSRMST_INSERT
IOCTL_SERIAL_SET_BREAK_ON
IOCTL_SERIAL_SET_BREAK_OFF
CX51x0 45Version: 1.6