2.4.2 CX90x0-N010 connections
In addition to the two Ethernet interfaces, this module features a DVI-I and two USB interfaces.
Note
System interface
The system interface CX90x0-N010 can only be used in CX90x0 system with large memory
(CX9001-x00x).
DVI-I interface
The DVI-I interface transfers analog and digital data and is suitable for connection to analog graphics cards
with 15 pin D-Sub connector and digital graphics cards with DVI-D output. The resolution at the screen or the
Beckhoff Control Panel depends on the distance (maximum 5 m).
The DVI interface uses VGA signals, so that the connection of CRT VGA monitors to the CX1000 system
using a DVI to VGA adapter is also possible.
This adapter is available as an accessory.
DVI-I socket:
Pin Assignment Pin Assignment Pin Assignment
1 TMDS Data 2- 9 TMDS Data 1- 17 TMDS Data 0-
2 TMDS Data 2+ 10 TMDS Data 1+ 18 TMDS Data 0+
3 TMDS Data 2/4
Shield
11 TMDS Data 1/3
Shield
19 TMDS Data 0/5
Shield
4 not connected 12 not connected 20 not connected
5 not connected 13 not connected 21 not connected
6 DDC Clock 14 + 5V Power 22 TMDS Clock
Shield
7 DDC Data 15 Ground ( +5V,
Analog H/V
Sync)
23 TMDS Clock +
8 Analog Vertical
Sync
16 Hot Plug Detect 24 TMDA Clock -
Pin assignment (cross)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beckhoff CX90x0 Series and is the answer not in the manual?

Beckhoff CX90x0 Series Specifications

General IconGeneral
BrandBeckhoff
ModelCX90x0 Series
CategoryController
LanguageEnglish

Related product manuals