System Functions
The system functions for the automatic convertible top are:
• Opening and closing the convertible top
• Comfort operation
• Check Control messages
Prerequisites for Opening and Closing the Top
In order to open and close the convertible top, the following conditions must be fulfilled:
• Terminal R ON
• Outside temperature above -12°C
• Trunk lid closed
• Speed lower than 40 km/h, (25mph)
- Speed lower than 50 km/h (31mph)
• The convertible top is allowed to finish opening or closing
until it reaches its end position.
- Speed above 50 km/h (31mph)
• The convertible top does not move.
- Speed above 70 km/h (44mph)
• Fault code memory entry A69A (Speed not permissible
in current convertible top position).
• Trunk partition lowered
• Battery voltage greater than 11.5 Volts
• Less than 5 opening and closing actions in succession (pump protection feature)
• The CAS must allow top operation.
(example: window status, terminal status)
41