English | 17
– Mark the centre of the laser line on wallA as point (vertically above or
below point).
– The discrepancy d between the two marked points and on wallA re-
veals the actual horizontal deviation of the measuring tool.
The maximum permitted deviation on the measuring distance of
2×5m=10m is as follows:
10m×±0.5mm/m=±5mm. The discrepancy d between points and
must therefore amount to no more than 5mm.
Checking the Levelling Accuracy of the Vertical Lines
For this check, you will need a door opening (on solid ground) which has at
least 2.5m of space either side of the door.
– Place the measuring tool 2.5m away from the door opening on a firm, flat
surface (not on a tripod). Select vertical mode with automatic levelling.
Aim the vertical laser line at the door opening and allow the measuring
tool to level in.
– Mark the centre of the vertical laser line on the floor of the door opening
(point), 5m away on the other side of the door opening (point) and on
the upper edge of the door opening (point).
Bosch Power Tools 1 609 92A 58R | (04.03.2020)