Safety Instructions
All instructions must be read and observed in order for
the measuring tool to function safely. The safeguards
integrated into the measuring tool may be comprom-
ised if the measuring tool is not used in accordance with
these instructions. Never make warning signs on the
measuring tool unrecognisable. SAVE THESE INSTRUCTIONS FOR FU-
TURE REFERENCE AND INCLUDE THEM WITH THE MEASURING TOOL
WHEN TRANSFERRING IT TO A THIRD PARTY.
u Warning! If operating or adjustment devices other than those spe-
cified here are used or other procedures are carried out, this can lead
to dangerous exposure to radiation.
u The measuring tool is delivered with a laser warning sign (marked in
the illustration of the measuring tool on the graphics page).
u If the text of the laser warning label is not in your national language,
stick the provided warning label in your national language over it be-
fore operating for the first time.
Do not direct the laser beam at persons or animals and
do not stare into the direct or reflected laser beam your-
self. You could blind somebody, cause accidents or damage
your eyes.
u If laser radiation hits your eye, you must close your eyes and immedi-
ately turn your head away from the beam.
u Do not make any modifications to the laser equipment.
u Do not use the laser goggles as protective goggles. The laser goggles
make the laser beam easier to see; they do not protect you against laser
radiation.
u Do not use the laser goggles as sunglasses or while driving. The laser
goggles do not provide full UV protection and impair your ability to see
colours.
Bosch Power Tools 1 609 92A 58R | (04.03.2020)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Professional GLL 2 and is the answer not in the manual?

Bosch Professional GLL 2 Specifications

General IconGeneral
Laser Diode635 nm, < 1 mW
Laser Class2
Leveling TypeSelf-Leveling
Self-Leveling Range±4°
Working Range10 m
Accuracy± 0.3 mm/m
Power Supply3 x 1.5 V LR6 (AA)
Tripod Thread1/4"
Storage Temperature-20°C to +70°C
Weight0.5 kg
Protection ClassIP54
Leveling Time4 sec
Operating Temperature-10°C to +50°C