CC408 | Quick Reference Guide | 3. Programming Parameters EN | 14
Bosch Security Systems | 6/04 | 4998152468B
3.10.14 System Status – Access Denied
(Code Retry)
Location
356 to 358
Location Default
Code retry limit
(0 = unlimited)
356 6
Tens digit 357 7
Units digit 358 12
3.10.15 System Status Reporting Options
Location
359
0 No Codepad Alarm Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
3.10.16 Test Report Time (Automatic)
Location
360 to 366
Location Default
Hour of day (tens digit) 360 0
Hour of day (units digit) 361 0
Minute of day (tens digit) 362 0
Minute of day (units digit) 363 0
Test Report (tens digit) 364 7
Test Report (units digit) 365 1
Repeat interval in days 366 0
3.10.17 Test Reporting Dialler Options
Location
367
0 No Codepad Alarm Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
3.11 Outputs Programming
3.11.1 Outputs
Location
368 to 397
Location Default
Output 1 (Default = Horn speaker)
Event Code 368 1
Event Code 369 14
Polarity 370 0
Time Base 371 0
Time Base Multiplier 372 0
Time Base Multiplier 373 0
Output 2 (Default = Fire alarm with verification)
Event Code 374 2
Event Code 375 7
Polarity 376 10
Time Base 377 2
Time Base Multiplier 378 1
Time Base Multiplier 379 5
3.11.1 continued
Location
368 to 397
Location Default
Strobe Output
(Default = Strobe – reset after 8 hours)
Event Code 380 2
Event Code 381 0
Polarity 382 6
Time Base 383 4
Time Base Multiplier 384 0
Time Base Multiplier 385 8
Relay Output (Default = Sirens running)
Event Code 386 1
Event Code 387 15
Polarity 388 1
Time Base 389 0
Time Base Multiplier 390 0
Time Base Multiplier 391 0
Codepad Buzzer
(Default = Entry/exit warning plus day alarm)
Event Code 392 0
Event Code 393 13
Polarity 394 2
Time Base 395 1
Time Base Multiplier 396 0
Time Base Multiplier 397 1
3.11.2 Event Codes
Event
Code
Description
0 0 EDMSAT – satellite siren (Output 1 only)
0 1 System armed
0 2 System disarmed
0 3 Armed in STAY Mode
0 4 Armed in AWAY Mode
0 5 Pre-arming alert
0 6 Exit warning (all zones sealed) and entry
warning
0 7 Exit warning
0 8 Exit warning finished
0 9 Kiss-off after end of exit time
0 10 Reserved
0 11 Entry warning
0 12 Entry warning and day alarm resetting
0 13 Exit warning and entry warning and day
alarm resetting
0 14 Day alarm resetting
0 15 Day alarm latching
1 0 Day alarm enabled
1 1 Telephone line fail
1 2 Kiss-off received
1 3 Fuse fail
1 4 AC fail
1 5 Low battery
1 6 Horn speaker fail
1 7 Sensor watch alarm
1 8 Codepad medical alarm
1 9 Codepad fire alarm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 880 CC408 and is the answer not in the manual?

Bosch Solution 880 CC408 Specifications

General IconGeneral
BrandBosch
ModelSolution 880 CC408
CategoryControl Panel
LanguageEnglish

Related product manuals