3.14.2 System Options 2
Location
425
Default
0
1 Codepad panic to be silent
2 Codepad fire to be silent
4 Codepad medical to be silent
8 Access denied (code retries) to be silent
3.14.3 System Options 3
Location
426
1 AC fail after 1 hour (Disabled = after 2 minutes)
2 Ignore AC fail
4 Pulse count handover allowed
8 Handover delay to be sequential
3.14.4 System Options 4
Location
427
Default
0
1 Panel to power up disarmed (if power reset)
2 Arm/disarm tracking on power up
4 Internal crystal to keep time
8 Radio keyswitch interface, night arm station, or
RE005 installed
3.15 Consumer Options Programming
3.15.1 Consumer Options 1
Location
428
Default
0
1 Test reports only when armed
2 Test report after siren reset
4 Auto arm in STAY Mode 1
8 STAY indicator to display day alarm status
3.15.2 Consumer Options 2
Location
429
1 Codepad display extinguish after 60 seconds
2 Single button arming allowed
(AWAY/STAY Modes 1 and 2)
4 Single button disarming allowed
(STAY Modes 1 and 2)
8 Alarm memory reset on disarm
3.15.3 Consumer Options 3
Location
430
1 Codepad fault beeps allowed
2 Use digit 3 for codepad duress alarm (instead of
digit 9)
4 Alarms activate sirens and strobe outputs in
STAY Modes 1 and 2
8 Reserved
3.16 Radio Input Options
Location
431
Default
0
1 Radio receiver (WE800)
2 Latching keyswitch input
3 Momentary keyswitch input
4 Reserved
3.17 Partioning
3.17.1 Partitioning Options 1
Location
432
Default
0
1 First to open/last to close reporting allowed
2 Area 1 codepad connected to data terminal
4 Request sirens from any area allowed
8 Master codepad to display AUX indicator when
on-line
3.17.2 Partitioning Options 2
Location
433
Default
0
1 Lock Area 1 to Receiver 1 and Lock Area 2 to
Receiver 2
2 User codes allowed to arm/disarm both areas at
same time ([code][0 #])
4 Reserved
8 Reserved
3.18 Zone Allocation Programming
3.18.1 Zone Allocations for Area 1
Location
434 to 441
Location Default
Zone 1 LED – Area 1 codepad 434 0
Zone 2 LED – Area 1 codepad 435 0
Zone 3 LED – Area 1 codepad 436 0
Zone 4 LED – Area 1 codepad 437 0
Zone 5 LED – Area 1 codepad 438 0
Zone 6 LED – Area 1 codepad 439 0
Zone 7 LED – Area 1 codepad 440 0
Zone 8 LED – Area 1 codepad 441 0
3.18.2 Zone Allocations for Area 2
Location
442 to 449
Location Default
Zone 1 LED – Area 2 codepad 442 0
Zone 2 LED – Area 2 codepad 443 0
Zone 3 LED – Area 2 codepad 444 0
Zone 4 LED – Area 2 codepad 445 0
Zone 5 LED – Area 2 codepad 446 0
Zone 6 LED – Area 2 codepad 447 0
Zone 7 LED – Area 2 codepad 448 0
Zone 8 LED – Area 2 codepad 449 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 880 CC408 and is the answer not in the manual?

Bosch Solution 880 CC408 Specifications

General IconGeneral
BrandBosch
ModelSolution 880 CC408
CategoryControl Panel
LanguageEnglish

Related product manuals