SERVICE TOOLS
This function allows the testing of individual com-
ponents and the ability to check switches for proper
function. This function also tests the Soft Heat server's
status on the brewer (in place or removed), and the
funnel sensor coil's frequency (diagnostic tool for
troubleshooting purposes only).
EXIT TO
NEXT FUNCTION
SCREEN
EXIT TO
NEXT FUNCTION
SCREEN
PRESS AND RELEASE
® SYMBOL
PRESS AND RELEASE
® SYMBOL
PRESS AND RELEASE
® SYMBOL
NEXT COMPONENT
TO BE TESTED
TEST OUTPUTS?
NO YES
TEST SWITCHES?
NO YES
BREW VALV E
ON NEXT OFF
SERVER REMOVED
IN PLACE
125.0 KHZ. 4
4 125.0 KHZ.
NOTHING PRESSED
TEST FREQUENCY?
NO YES
TEST SERVERS?
NO YES
SERVICE TOOLS?
NO YES
P2449
SERVER DETECT ?
NO DONE YES
P2310
Procedures to set server detect:
1. Press and hold the ® pad until the display reads
SET NEW RECIPES. Release the ®. Press and
release the ® pad until the display reads SERVER
DETECT.
2. The NO or YES flashes to indicate the current
selection.
3. Select YES to prevent brewing if the Soft Heat
server is not correctly positioned on the brewer
beneath the funnel.
NOTE: If YES is selected and a brew cycle is attempted
with a server not properly placed, the display will read
SERVER NOT IN PLACE.
4. Select NO to allow brewing without a Soft Heat
server in place. This is selected when brewing into
a container other than a Soft Heat Server.
5. When finished, press and release DONE. This will
save the new setting, exit the function screen and
advance to the next. Another alternative is to press
the
pad located on the front switch panel to
exit the SERVER DETECT function and return to
the MAIN SCREEN.
SERVER DETECT
This function allows the operator to prevent the start
of a brew cycle if a Soft Heat server is not positioned
correctly on the brewer.
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
34025 022509

Other manuals for Bunn SINGLE SH DBC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bunn SINGLE SH DBC and is the answer not in the manual?

Bunn SINGLE SH DBC Specifications

General IconGeneral
BrandBunn
ModelSINGLE SH DBC
CategoryCoffee Maker
LanguageEnglish

Related product manuals