CONTENTS
Page
SAFETY CONSIDERATIONS .....................1
INTRODUCTION
...............................4
ABBREVIATIONS
..............................4
17/19EX MACHINE FAMILIARIZATION
.............4-8
Machine Identification Label
.....................4
System Components
...........................4
Cooler
........................................8
Condenser
....................................8
Motor-Compressor
.............................8
Control Center
.................................8
Motor Starter
..................................8
Utility Vessel
..................................8
REFRIGERATION CYCLE
........................8
MOTOR/OIL REFRIGERATION
COOLING CYCLE (19EX CHILLERS)
............8,9
HERMETIC MACHINES (19 SERIES) LUBRICATION
CYCLE
...................................10,11
Summary
....................................10
Details
......................................10
OPEN-DRIVE MACHINES (17 SERIES)
LUBRICATION CYCLE
........................12
Summary
....................................12
Details
......................................12
STARTERS
...................................12
CONTROLS
................................ 12-45
Definitions
...................................12
ANALOG SIGNAL
DIGITAL SIGNAL
VOLATILE MEMORY
General
......................................12
PIC System Components
.......................14
PROCESSOR MODULE (PSIO)
STARTER MANAGEMENT MODULE (SMM)
LOCAL INTERFACE DEVICE (LID)
6-PACK RELAY BOARD
8-INPUT MODULES
OIL HEATER CONTACTOR (1C)
OIL PUMP CONTACTOR (2C)
HOT GAS BYPASS CONTACTOR RELAY (3C) (Optional)
OIL AUXILIARY RELAY (4C)
CONTROL TRANSFORMERS (T1-T4)
CONTROL AND OIL HEATER VOLTAGE
SELECTOR (S1)
OIL DIFFERENTIAL PRESSURE/POWER SUPPLY
MODULE
LID Operation and Menus
......................21
GENERAL
ALARMS AND ALERTS
LID DEFAULT SCREEN MENU ITEMS
MENU STRUCTURE
TO VIEW OR CHANGE POINT STATUS
OVERRIDE OPERATIONS
TO VIEW OR CHANGE TIME SCHEDULE OPERATION
TO VIEW AND CHANGE SET POINTS
SERVICE OPERATION
PIC System Functions
.........................35
CAPACITY CONTROL
ENTERING CHILLED WATER CONTROL
DEADBAND
PROPORTIONAL BANDS AND GAIN
DEMAND LIMITING
MACHINE TIMERS
OCCUPANCY SCHEDULE
Safety Controls
...............................35
SHUNT TRIP
Page
Default Screen Freeze .........................36
Motor Cooling Control (Hermetic Motors Only)
....36
Auxiliary Oil Pump Control (Open-Drive Machines
Only)
......................................36
Shaft Seal Oil (Open Drive Machines Only)
........36
Ramp Loading Control
.........................36
Capacity Override
.............................36
High Discharge Temperature Control
.............36
Oil Sump Temperature Control
..................38
Oil Cooler
....................................38
Remote Start/Stop Controls
.................... 38
Spare Safety Inputs
...........................38
Spare Alarm Contacts
.........................38
Condenser Pump Control
......................39
Condenser Freeze Prevention
...................39
Tower-Fan Relay
..............................39
Auto. Restart After Power Failure
................39
Water/Brine Reset
.............................39
Demand Limit Control, Option (Requires Optional
8-Input Module)
.............................40
Surge Prevention Algorithm
....................40
Surge Protection
..............................40
Lead/Lag Control
.............................40
COMMON POINT SENSOR INSTALLATION
MACHINE COMMUNICATION WIRING
LEAD/LAG OPERATION
FAULTED CHILLER OPERATION
LOAD BALANCING
AUTO. RESTART AFTER POWER FAILURE
Ice Build Control
..............................42
ICE BUILD INITIATION
START-UP/RECYCLE OPERATION
TEMPERATURE CONTROL DURING ICE BUILD
TERMINATION OF ICE BUILD
RETURN TO NON-ICE BUILD OPERATIONS
Attach to Network Device Control
...............43
ATTACHING TO OTHER CCN MODULES
Service Operation
.............................44
TO LOG ON
TO LOG OFF
HOLIDAY SCHEDULING
START-UP/SHUTDOWN/RECYCLE SEQUENCE
...45,46
Local Start-Up
................................45
Shutdown Sequence
...........................46
Automatic Soft Stop Amps Threshold
............46
Chilled Water Recycle Mode
....................46
Safety Shutdown
..............................46
BEFORE INITIAL START-UP
...................47-57
Job Data Required
............................47
Equipment Required
...........................47
Using the Utility Vessel and Pumpout System
.....47
Remove Shipping Packaging
...................47
Open-Drive Motor Electrical Connection
..........47
Open-Drive Motor Auxiliary Devices
.............48
Open Oil Circuit Valves
........................48
Tighten All Gasketed Joints and Guide Vane
Shaft Packing
...............................48
Check Machine Tightness
......................48
Refrigerant Tracer
.............................48
Leak Test Machine
............................48
Standing Vacuum Test
.........................49
Machine Dehydration
..........................51
Inspect Water Piping
..........................52
Check Optional Pumpout Compressor Water
Piping
....................................52
Check Relief Devices
..........................52
2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 17 and is the answer not in the manual?

Carrier 17 Specifications

General IconGeneral
BrandCarrier
Model17
CategoryChiller
LanguageEnglish

Related product manuals