EasyManuals Logo

Carrier 38MHRBQ24AA3 User Manual

Carrier 38MHRBQ24AA3
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
28
DIAGNOSIS AND SOLUTION (CONT)
Indoor / outdoor unit’s communication diagnosis and solution (E1)
Error Code E1
Malfunction Decision Conditions
Indoor unit does not receive the feedback from outdoor unit during 110 seconds and this condition
happens four times continuously.
Supposed Causes
S Wiring mistake
S Indoor or outdoor PCB faulty
Troubleshooting
Measure Vs., is it a positive fluctuation?
(Vs represents the voltage S and N of the
outdoor unit. Red pan-S, Black pan-N)
Power off, then restart the unit 2 minutes later
Replace the indoor main PCB.
Power on. Is the error resolved?
No
Check the indoor wiring connection
Yes
Check whether the
reactor is normal
Yes
No
Check the outdoor wiring connection
Replace the reactor
Yes
Replace the outdoor main PCB.
Power on. Is the error resolved?
Replace the indoor main PCB
No
Replace the outdoor main PCB.
Yes
No
Yes
Yes

Table of Contents

Other manuals for Carrier 38MHRBQ24AA3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carrier 38MHRBQ24AA3 and is the answer not in the manual?

Carrier 38MHRBQ24AA3 Specifications

General IconGeneral
BrandCarrier
Model38MHRBQ24AA3
CategoryAir Conditioner
LanguageEnglish

Related product manuals